SMC Corporation of America
Elite Part Number Search
Search Results "ASV310F-N01-07S-J"

Part Number Description: SPRING (IR1000-N01-X81)   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 120   Family Description: IR PRECISION REGULATOR   Class Code: 21   Part Code: 2   Reference Code:  J   Click here to report information errorImage shown may not match exact part number, SPRING (IR1000-N01-X81), AIRLINE EQUIPMENT, IR PRECISION REGULATOR, 21,

This product is obsolete. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

E l e c t r i c a l c a b l e m u s t n o t b e s u b j e c t e d t o excessive force. 2 When connecting the switch, use a spanner on the h e x a g o n f i t t i n g . N E V E R u s e t o o l s o n t h e s w i t c h body. 3 Do not use switch near corrosive materials. 4 The switch is not liquid sealed.

Model no. of NPT thread is AN101N01 and AN110-N01. Note 2) It indicates the inlet pressure for solenoid valve. Note 3) It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing. VEX Refer to page 5-10-13 for Precautions on these products.

Body Size: 3 (1/8 Basis), Port Size: N01 [Cylinder Side (NPT 1/8) Pilot Port (10-32UNF)], Applicable Tube OD: Ø6, Lock Nut: J (Round)

Body Size: 3 (1/8 Basis), Port Size: N01 [Cylinder Side (NPT 1/8) Pilot Port (10-32UNF)], Applicable Tube OD: 09 (Ø5/16"), Lock Nut: J (Round)

M5 R06 R07 N01 Port size M5 x 0.8 male thread 6 reducer type 1/4 inch reducer type Wetted parts material Pressure sensor: Silicon, O-ring: NBR Body: Stainless steel 304 Body: PBT With sensor cable (3 m) 41 g 38 g Mass Without sensor cable 7 g 3.8 g -12No.PS-OME0004-G Analog output Range Rated pressure range A B C For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -101 to 101 kPa -101

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Pad Diameter: ø40, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: S (Silicone Rubber), Buffer Body Material: J (Aluminum Alloy), Buffer Stroke: 50, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A18 (M18 x 1.5)

Pad Diameter: ø125, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: U (Urethane Rubber), Buffer Body Material: J (Aluminum Alloy), Buffer Stroke: 50, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A22 (M22 x 1.5)

Pad Diameter: ø125, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: U (Urethane Rubber), Buffer Body Material: J (Aluminum Alloy), Buffer Stroke: 100, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A22 (M22 x 1.5)

This is a legacy product, and replaced byZSE20A-Y-N01-J, VACUUM SWITCH, HIGH PRECI *LQA, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .38131 lb

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)