Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from Liability 1.
If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from Liability 1.
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
Manual lock Throttle CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Spacer (Y200-A) Regulator (AR20 series) WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
PUSH (2)Air operated type Connect a regulator to the pilot port as Regulator for Pilot maintenance manual. Refer to the maintenance manual for the replacement parts. (3) When making a request for maintenance to SMC Remove accessories such as fittings mounted on the booster shown below. AR20 and AW2000 are recommended for the pilot regulator.
If option “H” is selected, a set nut will be included with the product (e.g., AR20-01GH-A).
The set nut can also be purchased as an individual part. Refer to the “Option/Part Nos.” section in the AR series catalog.
Note that the type with a bracket always includes a set nut.
ISE35 Series Dimensions ISE35-N ISE35-R 26.7 27.8 (11.3) 12.1 3.3 OUT MPa PRESSURE s (13) 1.5 (34) s PRESSURE MPa OUT (13.2) Lead wire with connector ZS-32-A Brown DC (+) Black OUT (1) Blue DC () + O 2020 128 A
Note 6) : For thread type: NPT only 1075 A
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Do not use the spacer (with a bracket) of the AC series unit for high-pressure specification (special order part number suffix “-X425”) products.
When assembling high-pressure special order products, AF20 to 60-*-A-X425 and AR20 to 60-*-B-X425, prepare a nipple for installation.
Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BONNET, AR20, AIRLINE EQUIPMENT, AR MASS PRO, 21, AR MASS PRO NO SIZE RATING, 0.04123 lb
SMC Regulator (With Backflow Function) AR20(K)-B To AR60(K)-B Series.Features· Specifications with a backflow function feature an inbuilt mechanism for quickly exhausting the air-pressure at the outlet side.
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is
This is a legacy product.
Body Size: 20, Backflow: K (w/Backflow Function), Thread: Rc, Port Size: 02 (1/4), Options: B (w/Bracket), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Y (Upward), Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 20, Backflow: w/Backflow Function, Thread: Rc, Port Size: 1/4, Options: w/Bracket, Set Pressure: 0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Upward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa, Made to Order: -
Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge. The modular design of the AR series connects with other SMC air preparation equipment. "REGULATOR. Y.