Case: [Resin] Polycarbonate Case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With bowl guard, Specification: Applicable part number: AL30-A, Type: Case assembly
fluid discharge temp. 2 AL19 : High circulating fluid return temp. 3 Unused 4 AL21 : High circulating fluid discharge pressure 5 AL22 : Low circulating fluid discharge pressure Alarm flag 2 6 Unused 7 AL24 : Memory abnormal 8 AL25 : Contact input 1 signal detection 9 AL26 : Contact input 2 signal detection 10 AL27 : Forced stop 11 AL28 : Maintenance notice 12 AL29 : Communication error 13 AL30
error AL20 Memory error AL21 DC line fuse cut AL22 Circulating fluid discharge temp. sensor failure AL23 Circulating fluid return temp. sensor failure AL24 Compressor intake temp. sensor failure AL25 Circulating fluid discharge pressure sensor failure AL26 Compressor discharge pressure sensor failure AL27 Compressor intake pressure sensor failure AL28 Pump maintenance AL29 Fan maintenance AL30
error AL20 Memory error AL21 DC line fuse cut AL22 Circulating fluid discharge temp. sensor failure AL23 Circulating fluid return temp. sensor failure AL24 Compressor intake temp. sensor failure AL25 Circulating fluid discharge pressure sensor failure AL26 Compressor discharge pressure sensor failure AL27 Compressor intake pressure sensor failure AL28 Pump maintenance AL29 Fan maintenance AL30
pump operation Stop AL15 Stop Refrigerant circuit pressure (high pressure side) drop AL20 Stop Memory error AL22 Stop Circulating fluid discharge temp. sensor failure AL24 Stop Compressor intake temp. sensor failure AL26 Stop Compressor discharge pressure sensor failure AL27 Stop Heat exchanger inlet temp. sensor failure AL28 Continue Pump maintenance AL29 Continue Fan motor maintenance AL30
Alarm message AL38 Compressor discharge temp. rise AL39 Internal unit fan stoppage AL40 Dustproof filter maintenance Note 1) AL41 Power stoppage AL42 Compressor waiting AL43 Fan breaker trip Note 1) AL44 Fan inverter error Note 1) AL45 Compressor breaker trip Note 2) AL46 Compressor inverter error AL47 Pump breaker trip Note 2) AL48 Pump inverter error AL49 Air exhaust fan stoppage Note 3) AL30
Alarm message AL38 Compressor discharge temp. rise AL39 Internal unit fan stoppage AL40 Dustproof filter maintenance Note 1) AL41 Power stoppage AL42 Compressor waiting AL43 Fan breaker trip Note 1) AL44 Fan inverter error Note 1) AL45 Compressor breaker trip Note 2) AL46 Compressor inverter error AL47 Pump breaker trip Note 2) AL48 Pump inverter error AL49 Air exhaust fan stoppage Note 3) AL30
The AL30/40/50/60 are equipped with a check valve on the body.
Therefore, lubricant can be supplied by removing the lubrication plug even when the product is pressurized.
Loosen the lubrication plug slowly, by about 1 turn, to release the pressure inside the bowl.
When pressure in the bowl is released, remove the lubrication plug and supply lubricant.
In addition, old AL series lubricators (e.g., AL3000-02) from older AC series modular F.R.L. units (4 digits: AL□□□□) can be replaced with lubricators from the AL□□-A series (AL30-02-A). (The bowl assembly cannot be replaced on its own.)
A 1000 cm2 tank type is available for standard AL30 to 60 series products.
Details on the 1000 cm2 tank type can be found here.
For AL30-A to AL60-A series lubricators, when the lubrication plug is opened under the pressure of the lubricator, air bubbles may be generated at the end of the oil passage (sometimes they are not). This is also caused by the bowl’s internal pressure being lower than the outlet pressure.
Body Size: 30, Backflow: K (w/Backflow Function), Thread: Rc, Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 30, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Relief, Reverse Flow Function (Relief): No, Supply Side Connection Type: Rc, Supply Side, Connection Diameter: 3/8, Flow Direction: [Left] From Right to Left, Control Side Connection Type: Rc, Control Side
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 3/8, Option: Assembly of a Bracket & Set Nuts, Semi-Standard: 1 + R
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: 1R (1 + R)
Body Size: 25, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: 1R (1 + R)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 3/8, Option: Assembly of a Bracket and Set Nuts, Semi-Standard 1: 0.02 to 0.2MPa Setting, Semi-Standard 2: Flow Direction: Right to Left, Made to Order: -
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Relief, Reverse Flow Function (Relief): [Included] Yes, Supply Side Connection Type: Rc, Supply Side, Connection Diameter: 3/8, Flow Direction: [Left] From Right to Left, Control Side Connection Type: Rc