SMC Corporation of America
Elite Part Number Search
Search Results "52-IP8001-034-EW-3"

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: None (Standard), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: N (Rc1/4 - NPT1/2)

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: C (Fork Lever-type Fitting M), External Scale Plate: H (w/External Scale Plate)

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: Fork Lever-type Fitting S, External Scale Plate: None, LCD Window: Body w/LCD Window, Connection, Air - Electric: -, ATEX Temperature: -

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: None (Standard), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: NPT1/4 - M20x1.5, ATEX Temperature: -

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: None (Standard), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: G1/4 - M20x1.5, ATEX Temperature: -

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: None (Standard), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: Rc1/4 - NPT1/2, ATEX Temperature: -

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: Fork Lever-type Fitting M, External Scale Plate: w/External Scale Plate, LCD Window: -, Connection, Air - Electric: -, ATEX Temperature: -

Type: Relay Device, Type: Smart rotary type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: S, Lever unit: N/A, External scale plate: N/A, Body cover with window for LCD: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: ATEX Directive Category

Type: Relay Device, Type: Smart rotary type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: N/A, Lever unit: N/A, External scale plate: Available, Body cover with window for LCD: N/A, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: ATEX Directive

Type: Relay Device, Type: Smart rotary type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: N/A, Lever unit: N/A, External scale plate: N/A, Body cover with window for LCD: N/A, Air connection port: Rc1/4, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX Directive

IP8000 E/P positioner is more compact than the IP6000 with?improved visibility of the pressure indicator.? Other features include an improved enclosure protection?IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.? The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.??The

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  The

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  The

Repl acem ent i s necessary i n that case. ( W hen pressure drop reach 0. 1M Pa) El em ent ( gasket , ori ng accessory) m odel num ber: AM G EL*** *** i s AM G si ze sym bol . ( Ex: AM G EL150) H exagon socket head bol t O ri ng( N ew ) O ri ng( U sed) G asket( N ew ) G asket( U sed) El em ent ( N ew ) El em ent ( U sed) Case H ow t o repl ace el em ent Compressor Water separator Air filter

2 Safety Instructions Continued 1) Inspection and maintenance of machinery/equipment should only be 3 Specifications Continued 3 Specifications Continued DOC1003077 3.5 Model number of product Item Spec. performed after confirmation of safe locked-out positions.

If load is used for a relay, use an appropriate relay to maximize the life. 3. Exceeding specifications for load current, voltage, temperalure, impact, etc. could result in malfunction and operational failure . Please be sure to read the specifications thoroughly before use. 3.

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: D (Fork Lever-type Fitting S), External Scale Plate: H (w/External Scale Plate), LCD Window: None, Connection, Air - Electric: M (Rc1/4 - M20x1.5)

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: D (Fork Lever-type Fitting S), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: 2 (NPT1/4 - M20x1.5)

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: None (Standard), External Scale Plate: H (w/External Scale Plate), LCD Window: None, Connection, Air - Electric: M (Rc1/4 - M20x1.5)

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: Fork Lever-type Fitting S, External Scale Plate: w/External Scale Plate, LCD Window: None, Connection, Air - Electric: Rc1/4 - M20x1.5, ATEX Temperature: -