Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Manufacturable stroke range [mm] 11-LEFS16 V V V V V V V V V V 50 to 500 11-LEFS25 V V V V V V V V V V V V 50 to 600 11-LEFS32 V V V V V V V V V V V V V V V V 50 to 800 11-LEFS40 V V V V V V V V V V V V V V V V V V 150 to 1000 * Please consult with SMC for
1 V 1.8 V 5 V Current output 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C Voltage output 1 V 1.48 V 5 V Current output 4 mA 5.92 mA 20 mA Rated flow [L/min] Sensor model Minimum Maximum PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0010-J Dimensions PF3W504
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
Type Description Note Model symbol O A B BB C D F1 G H J1 J2 K Q R1 R2 U V QW NW SI unit part no.
bushing / / (Except r/i6) ~~~-v : :, ~,-lI ---wCK z ' S z .. ' : -zz. . .. , ..
M5 x 0.8 Body side VZA222-P-M5 M5 x 0.8 0.13 0.35 0.52 0.15 0.43 0.60 N.O. M5 x 0.8 Body side VZA214-1P-01 M5 x 0.8 0.22 0.35 0.85 0.25 0.30 1.0 N.C. Rc 1/8 Sub-plate side VZA214-2P-01 M5 x 0.8 0.22 0.35 0.85 0.25 0.30 1.0 N.C. Rc 1/8 Body side VZA224-1P-01 M5 x 0.8 0.22 0.35 0.85 0.21 0.25 0.90 N.O. Rc 1/8 Sub-plate side VZA224-2P-01 M5 x 0.8 0.22 0.35 0.85 0.21 0.25 0.90 N.O.
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, Kpa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, Kpa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
DIN type 5 pins Number Description Function Description Function 2 SW+ Number 1 Sensor power supply + Open 2 3 4 For solenoid valve +24 V 1 SV24V 2 N.C. 1 VQC 3 For solenoid valve 0 V 2 SV0V 3 SW Sensor power supply Protective ground 3 PE 4 SIGNAL Sensor input signal 4 1 5 5 SQ
Caution Caution When the VEX3420 air operated power valve is delivered from our factory, the M5 threaded pilot ports P1 and P2 in the cover are open and the Rc1/8 pilot port in the subplate is plugged. Before connecting pipes to P1 and P2 ports in the subplate, remove the 1/8 plug from the subplate and put M5 plugs into P1 and P2 ports in the cover.
/O.D.: 5/8 to 11/16 Series KKA Fluid: Air, Water Port size: 6A to 50A (1/8 to 11/2) Port size: M5 to 25A(3/4) Brass One-touch Fittings Stainless Steel 316 One-touch Fittings Series KQB Fluid: Air, Water Series KQG Fluid: Air, Water, Steam Applicable tubing O.D.: 4 to 12 Applicable tubing O.D.: 4 to 12 Stainless Steel 316 Insert Fittings Fluoropolymer Fittings Series KFG Fluid: Air
OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) JEMANET (JPCN-1) Mitsubishi Electric Corp.: CC-LINK System Rockwell Automation: Allen Bradley Remote I/O (RIO) System NKE Corp.: Uni-wire H System Kit T1 With terminal blocks 1 to 12 stations T B kit (Terminal block box kit) BB C D F1 J1 J2 K Q R1 R2 U V G H 2 to 12 stations SD SU Box mounting
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
1 Floating Joint Series JA/JAH/JB/JS The floating joint can absorb any off-centering or loss of parallel accuracy between the cylinder and the driven body. RE A B REC CX Centering is unnecessary. CY A high level of machining accuracy is unnecessary. Spherical rotation MQQ M The installation time is dramatically reduced. RHC It is compact and is suitable for high tensile stresses.
1 Floating Joint Series JA/JAH/JB/JS The floating joint can absorb any off-centering or loss of parallel accuracy between the cylinder and the driven body. RE A B REC CX Centering is unnecessary. CY A high level of machining accuracy is unnecessary.
Floating Joint JA/JAH/JB/JS Series RoHS The floating joint can absorb any off-centering or loss of parallel accuracy between the cylinder and the driven body. J J Centering is unnecessary. A high level of machining accuracy is unnecessary. Spherical rotation The installation time is dramatically reduced. It is compact and is suitable for high tensile stresses.