H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
/8 (External pilot port) With connector on D side (FD) 2-6-12 13 Base Mounted Series VQ5000 Plug-in Unit Bottom ported drawing With connector on U side (FU) 106 46.8 59.2 VQC 83.5 9 9 55.5 M5 ground screw 2n-Rc 1/2 4(A), 2(B) port SQ 34.5 VQ0 n U side X 12 VQ4 B 2 A 4 6 B A VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200
1) 75 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) 80 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) 85 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) 90 + 30 (n 2) (n = 2, 4, 6, 8) Note 1) n (Same surface) 90 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 95 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 100 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 105 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 110 + 100 (n 2) (n = 2, 4, 6, 8) Note 1) 125
Load: F [N] LEY32 Selection example) Based on the graph shown on the right side, Jig weight: 0.5 [kg] 5 [N] Product stroke: 300 [mm] Therefore, the lateral load on the rod end is in the allowable range. 10 LEY25 1 Stroke [mm] 0 100 200 300 400 500 600 Based on the above calculation result, the LEY25B-300 is selected.
B A B A A A B A B A B A 9 A A A A A A A 143 163 42 80 34.5 R4.5 B B 9 B B B 55.5 SI unit 10 101 Stations D-side U-side 1 2 3 4 5 6 7 8 n Formulas L1 = 25n + 106 (Maximum 16 single wiring stations) L2 = 25n + 192 n: Stations n L L1 L2 1 131 217 2 156 242 3 181 267 4 206 292 5 231 317 6 256 342 7 281 367 8 306 392 9 331 417 10 356 442 11 381 467 12 406 492 13 431 517 14 456 542 15 481 567
Stations (Maximum 16 stations) Formula L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) L n Dimensions L n Dimensions 8 263 276 L1 L2 7 238 251 8 263 276 L1 L2 6 213 226 7 238 251 5 188 201 6 213 226 4 163 176 5 188 201 3 138 151 4 163 176 1 2 113 126 3 138 151 1 2 113 126 88 101 88 101 L n L n 9 288 301 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 9 288
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter
Equation L1=31n+29, L2+31n+14 n: Station 2 91 76 3 122 107 4 153 138 5 184 169 6 215 200 7 246 231 8 277 262 L L1 L2 5.1-25 VEX3 Manifold/VVEX4-1 VVEX4-1 Applicable valve: VEX3420/E3422 VVEX4-2 Applicable valve: VEX3420/E3422 Valve mounting side Internal pilot Common external pilot VEX AN AMC L: Dimensions n L1=46n+31, L2+46n+15 n: Station 2 123 107 3 169 153 4 215 199 5 261 245 6 307 291
Re ~ t~ur.:.: n:.' s~pr~i::ng !'...-__-I___ _ P :.
Note 2) In placing an order of mechanical seal set (service parts), inform us of the complete model number and the production lot number of the product in use. 40 Technical Data C O N T E N T S M Magnet pump P. 195 Mechanical seal pump P. 194 N Non-return valve P. 195 NRTL (National Recognized Test Laboratories) P. 199 O Offset function P. 197 ON/OFF temperature control P. 197 Overload relay
( ) 6H9 depth 6 +0.030 0 n x 6.6 7 LEC 76 LEC S 150 15 LEC SS-T D x 150 (= E) 60 B LEC Y Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more because of round chamfering.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -