SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXQ16-10C-M9NL"

HRZ Series 8.1 Specification 8-3 HRX-OM-I051 Chapter 8 Appendix Specification for ethylene glycol solution (low temperature) Table 8-4 Specification for Ethylene Glycol Aqueous Solution (Low Temperature) Model HRZ001-L1 HRZ002-L1 HRZ004-L1 HRZ008-L1 Cooling method Water cooled refrigerant Cooling capacity*1 (50Hz/60Hz) kW 1.0 (At -10C) 2.0 (At -10C) 4.0 (At -10C) 8.0 (At -10C) Operating

) Circulating fluid system Cooling water system Electrical system 2.0 (at 10C) 1.0 (at 20C) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note

/Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump Weight (dry state) kg 151 154 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less.

to 70C, With auto switch: 10C to 60C (No freezing) Mounting Bracket Part No.

to 70C Ambient and fluid temperature With auto switch: 10C to 60C (No freezing) Auto switch specifications and the proper mounting positions for stroke end detection are the same as those for double acting, single rod type.

MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa 8 120 0.6 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa F 0.6 MPa 80 0.4 MPa 0.5 MPa 4 60 0.3 MPa 40 0.4 MPa 2 0.25 MPa 20 0.3 MPa F 0 10 20 30 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) Internal Grip MHZ2-10C/MHZL2-10C MHZ2-32C MHZA2, MHZ2, MHZL2 250 Pressure 0.7 MPa Pressure 0.7 MPa

If the set temperature is repeatedly changed by 10C or more, the thermo-con may fail in short periods of time. Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1.

Low concentrations, however, can lead to freezing when circulating fluid temperature is 10C or lower and cause the thermo-chiller to break down. 5. A magnet pump or mechanical seal pump is used as the circulating pump for the circulating fluid.

Specifications Suction flow rate of vacuum type (Reference values) Bore size (mm) 6 10/16 Item 1.05MPa 0.7MPa 0.14MPa Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed 1 Size Suction flow rate l/min (ANR) 6/10/16 0.08MPa (Air cushion 0.1MPa) Without auto switch : 10C to 70C, With auto switch : 10C to 60C (With no condensation) Stroke

Specifications Suction flow rate of vacuum suction type (Reference values) Bore size (mm) Item 20/25/32/40/50/63/80/100 1.5MPa 1.0MPa 0.05MPa Proof pressure Maximum operating pressure Minimum operating pressure Bore size Suction flow rate l/min (ANR) 20/25/32/40 50/63/80/100 10 20 Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature 10-/

Trace the arrow mark , starting with the point A at the pressure dew point 10C to find the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark , starting with the point B to find the intersection C at the atmospheric pressure dew point. 3.

Trace the arrow mark , starting from point A at a pressure dew point of 10C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. Trace the arrow mark , starting from point B to obtain the intersection C at the dew point under atmospheric pressure.

L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C

Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.

Fluid and fluid temperature Air: 10 to 60C (Dew point temperature: 10C or less) Withstand pressure 2.0 MPa Max. system pressure 1.0 MPa Ambient temperature 20 to 60C Valve leakage*1/External leakage*1 Air 1 cm3/min (ANR) or less Mounting orientation Unrestricted Enclosure*2 IP67 (IP65 for the DIN terminal) Standards*3 CE/UKCA Operating environment Location without the presence of corrosive

) Facility water: 50F (10C) 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) HED007 60 80 100 120 140 F 40 2800 2400 Facility water: 95F (35C) Heating capacity (W) Facility water: 77F (25C) 2000 1600 1200 Facility water: 50F (10C) 800 400 0 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) 178 Chemical Thermo-con

Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C

to 70C With auto switch: 10C to 60C (With no condensation) Proof pressure Max. operating pressure Min. operating pressure Mounting Bracket / Part No.

Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke

Condition Condition Inlet air temperature 40C Inlet air temperature 55C Outlet air pressure dew point 10C Outlet air pressure dew point 10C Ambient temperature 35C Ambient temperature 35C Inlet air pressure 0.5MPa Inlet air pressure 0.7MPa Air flow 1200 l/min (ANR) Air flow 350 l/min (ANR) Power supply frequency 60Hz Power supply frequency 50Hz A = 0.85 based on conditions , and B-1 = 0.95