to +60C, -10C to +70C without magnet Piston speed [mm/s] 50 1000 [mm] Standard strokes Standard stroke Max.
Under conditions of inlet air pressure: 0.7MPa, inlet air temperature: 35C, ambient temperature: 32C, outlet air pressure dew point:10C. Note2)
If the set temperature is repeatedly changed by 10C or more, the thermo-con may fail in short periods of time. 1. Use a fluid that is listed in the specifications. 2. Deionized water (pure water) [with an electric conductivity of approx. 1 S/cm] can be used, but may lose its electric conductivity.
For Use in North, Central and South America Refrigerated Air Dryer (UL, CSA Standards) Applicable for the high-temperature environments Ambient temperature : Max. 113F (45C) Inlet air temperature : Max. 149F (65C) Air flow capacity * IDFB90-23, Dew point of 50F (10C) 459 SCFM (780 m3/h) (13% increase compared to the current model) Power supply voltage Single-phase 230 VAC (60 Hz) Single-phase
Action Double acting Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.08 MPa 0.2 MPa Piston speed 50 to 500 mm/sec* 15 to 300 mm/sec* Ambient and fluid temperature Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) 5C to 60C Cushion Air cushion None Stroke length tolerance Up to 250: +1.0 0 , 251 to 1000: +1.4 0 , 1001 to 1500:
to 70C With auto switch: 10C to 60C (No freezing) MWB-UT CP96N C96N Lock Unit Accessories Auto Switch Made to Order Double Acting, Single Rod Double Acting, Double Rod Lubricant Not required (Non-lube) Piston speed 50 to 1000 mm/s*1 Stroke length tolerance Up to 500 st: +2.0 0 , 501 to 1000 st: +2.4 0 , 1001 to 1500 st: +2.8 0 , 1501 to 2000 st: +3.2 0 Cushion Air cushion on both ends +
OFF *1 10C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value. AL12 CH1 TEMP READY ALARM OFF *1 +1/-1C 3 CH2 High Temp.
(between lead wire and case) -10C to 60C CE marking Dimensions (mm) D-Y7BWL-900 M2.5 x 4l Slotted set screw Indicator light Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light.
Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Rubber bumper, Air cushion Not required (Non-lube) JIS 2nd class Ambient and fluid temperature Cushion Lubrication Thread tolerance Stroke tolerance CL Non-locking and locking styles are standard for manual release. +1.4 0 MLGC Rubber bumper Air cushion 50 to 750mm/s 50 to 1000mm/s Piston speed CNA Basic
Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 B = 0.95 based on conditions q, w and e 1 C = 1.00 based on
Effective value N Action Internal gripping force External gripping force 4 55 9.8 10 MHZ2-10D (N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C
Furthermore, when controlling for low speed or controlled output, use clean air (atmospheric pressure dew point temperature of 10C). Installation of a mist separator (filtration degree 0.3m or less) is also recommended. 3. Use a metal seal type when using solenoid valves for cylinder actuation.
Furthermore, when controlling for low speed or controlled output, use clean air (atmospheric pressure dew point temperature of 10C). Installation of a mist separator (filtration degree 0.3 m or less) is also recommended. 3. Use a metal seal type when using solenoid valves for cylinder actuation.
MXP6 MXP8, 10, 12, 16 L2 L2 Shock absorber model RB0805 RB0805 RB0806 Applicable size MXP10 MXP12 MXP16 L2 Table 2 L2 (mm) 10 (one side only) 10 (one side only) 9 8 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP8-10C MXP8-20C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Stroke Adjustment Urethane bumper Lock nut Lock nut MXP6 MXP8, 10, 12, 16 Shock Absorber Loosen the lock nut, adjust
Series SV3000,SV4000 DIN rail holding screw tightening torque: 1.4Nm Supply/Exhaust block assembly Circular connector (type 10C) EX250 (type 10S1W) D-sub connector (type 10F) , , and are not included with the supply/exhaust block assembly. Included only with the DIN rail mount type.
Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C (No freezing) Rubber bumper, Air cushion Not required (Non-lube) JIS 2nd class CL Ambient and fluid temperature Cushion Lubrication Thread tolerance Stroke tolerance MLG +1.4 0 CNA Rubber bumper Air cushion 50 to 750mm/s 50 to 1000mm/s Piston speed CNG Basic, Axial foot, Front flange, Rear flange, Single clevis, Double
KJ12D 12 50 16 13 16 M12 x 1.25 22 32 50, 63 KJ16D 16 64 21 15 26 M16 x 1.5 28 42 80, 100 M20 x 1.5 KJ20D 20 77 25 33 15 26 50 6-12-11 Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C
Temperature range which can be set with the Thermo-chiller 10C to 35C Example) Facility water temperature of customers machine: 15C Temperature difference between the circulating fluid and facility water is: 50 15 = 95F (35C). 4.What is the kW for the required cooling capacity?
Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C (No freezing) Operating humidity range 90% RH or less (No condensation) Storage temperature range 10C
Rc NPT G Cylinder stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Specifications Made to Order Piston rod/ Guide rod material (Hard chrome plating) 32 40 50 63 80 100 Double acting Air 1.5 MPa 1.0 MPa 0.12 MPa 0.14 MPa 10C to 60C (No freezing) Rubber bumper on both ends Not required (Non-lube) +1.5 0 mm Lube-retainer Part no.