-V 200 to 230 Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -10- 2.3 Construction LEKFS Motor : In-line (AC servo motor) Component Parts No.

to 500 88 14 131 150st or more 350 to 600 90 14 136 200st or more 350 to 800 101 15 156 250st or more 350 to 1000 116 16 202 With auto switch MGCB Bore size SMGC Bore size #1(#1+#4) Note) Dimentions with a * mark is irrelevant to models without a rear plate. 3.20-10 Compact Guide Cylinder Series MGC Front Face Mounting Flange/With Rear Plate MGClFl-l-R CL MLGC CNA CB CV/MVG CXW CXS CXT MX

Purchasing order is available in units of 10 pieces. 2-4-111 2-4-112

Standard stroke 6 10 15 20 25 32 40 50 63 6mm 10mm 15mm Port thread type 20mm Bore size 6, 10, 15 Type M thread Rc NPT G Symbol 25mm 32mm Nil 20, 25, 32, 40 40mm TN TF 50, 63 50mm 63mm Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) 300 6 50, 100, 150, 200 500 10 15 20 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100

(mm) 40 50 63 80 CA2-B04 CA2-B05 CA2-B06 CA2-B08 CA2-B10 +0.058 0 57 35 11 65 15 85 10 9 17 8 40 52 60 165 10 +0.070 0 57 35 11 65 18 85 10 9 17 8 40 52 70 183 12 +0.070 0 67 40 13.5 80 25 105 12.5 11 22 10 50 66 85 196 16 +0.084 0 93 60 16.5 100 31.5 130 15 13.5 24 12 65 90 102 235 20 100 +0.084 0 93 60 16.5 100 35.5 130 15 13.5 24 12 65 90 116 256 25 10 Series CA2 Dimensions of Accessories

Purchasing order is available in units of 10 pieces. d d KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing

ISO Class 6 upper limit ISO Class 6 upper limit 10 10 LEJ LEL 10 10 Suction flow rate: 0 L/min Particle concentration [particles/m3] Particle concentration [particles/m3] LEM ISO Class 5 upper limit Suction flow rate: 0 L/min LEY 10 10 LES ISO Class 5 upper limit Suction flow rate: 10 L/min LEPY LEPS 1000 1000 Suction flow rate: 20 L/min LER ISO Class 4 upper limit ISO Class 4 upper limit

Selection Graph [Graph 2] Allowable load mass by stroke 10 [Graph 1] Allowable load mass by stroke 6 10 10 Load mass [kg] Load mass [kg] y, z + A 200 y, z + A 300 y, z + A 100 1 1 0 100 200 300 400 500 600 0 100 200 300 400 Stroke [mm] Stroke [mm] [Graph 4] Allowable load mass by stroke 20 [Graph 3] Allowable load mass by stroke 15 100 10 y, z + A = 0 Load mass [kg] Load mass [kg] y, z

Core wire colors Brown: Not connected Note 1), 24 VDC 10% (Control power supply) Note 2) White: 24 VDC +10%/5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2) Black: 0 V (Solenoid valve power supply) Gray: Not connected Brown: 24 VDC +10%/5% (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: 24 VDC 10% (Control power

Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing

400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact SMC if the maximum stroke will be exceeded.

400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact P/A if the maximum stroke will be exceeded.

0.4 MPa External grip 0.4 MPa 0.3 MPa MHK 0.3 MPa 10 10 F 0.2 MPa 0.2 MPa MHS MHC 0 0 10 10 20 20 30 30 40 40 Gripping point L (mm) Gripping point L (mm) F F MHT MHS4-25D MHS4-25D MHY 50 50 Pressure 0.6 MPa Pressure 0.6 MPa MHW 40 40 F Gripping force (N) Gripping force (N) 0.5 MPa 0.5 MPa -X 30 30 Internal grip 0.4 MPa 0.4 MPa 20 20 MRHQ 0.3 MPa 0.3 MPa 0.2 MPa 0.2 MPa 10 10 MA D0 0 10 10

Page 603-10 JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT Provided by customer (3 m) Communication cable To PWR Page 603-10 Power supply for controller 24 VDC Power supply plug (Accessory) Page 603-10 Options Teaching box Controller setting kit Conversion cable Note) Page 603-10 P5062-5 (0.3 m) Page 603-10 (With 3 m cable) LEC-T1

Note 1) 5 10 5 10 D-A9 D-A9V D-M9V 5 Note 1) 5 D-M9 10 Note 1) 10 5 Note 2) D-M9W 10 Note 2) 10 5 Note 2) D-M9WV D-M9AV 10 5 Note 2) D-M9A 10 Note 2) 15 15 D-P3DW Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.