Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

FILTER ELEMENT (AFW20-N02-*). AIRLINE EQUIPMENT. AFW NO SIZE RATING. 21.

This is a legacy product, and replaced byAS3211F-N02-11S

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Body Option: 1 (External Pilot), Port Size: N02 (NPT1/4), Style: 06 (Roller Plunger), Suffix: S (Roller Material Hard Steel)

This is a legacy product, and replaced byVFM250-N02-01 VALVE, MECH L (NYLON). VALVE. VM BODY PT 1/4. .68200 lb.

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VM BODY PT 1/4, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FI, VM BODY PT 1/4, 0.2442 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VM BODY PT 1/4, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FI, VM BODY PT 1/4, 0.92594 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MECH VALVE DUAL NON-EXCH ACT, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FI, VM BODY PT 1/4, .24420 lb

The VM series is a mechanical, poppet valve. Their compact size requires little mounting space. The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 19mm 2 (1.0), Fluid temperature: -5 to 60 C (no freezing), Port size (nominal size): Rc(PT) 1/4 (8A), MECH VALVE DUAL NON-EXCH ACT, VALVE,