Please change the parameter in the initial setting. *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 12 - LECSS LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter Para. No.
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
Cooling Capacity HRS100-A -20/40(50 Hz) HRS100-A -20/40(60 Hz) 14 14 12 12 Ambient temperature 90F (32C) Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 90F (32C) Ambient temperature 104F (40C) Ambient temperature 104F (40C) 8 8 6 6 4 4 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5]
XSA1 4.5 6 XSA2 7 8 XSA3 10.5 11.5 Reverse pressure potential 0.5 MPa(G)*1 Weight New New 18% *1 XSA1-12 (Refer to the Specifications on page 3.) 0.5 kg 0.41 kg lighter *1 Rated voltage *1 XSA2-2 32 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC 24 V, 12 V Applications Photovoltaic cell manufacturing Semiconductor manufacturing LCD manufacturing New New Female thread type (Rc,
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 250 x 4.186 x 103 x 12 900 = = 13953 [J/s] 14.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 14.0 [kW] x 1.2 = 1 x 250 x 60 x 1.0 x 103 x 12 15 x 860 16.8 [kW] = Thermo-chiller Q x t: Heat capacity [kJ] 13953 [W] = 14.0 [kW] Water bath 20C Cooling capacity = Considering
15 60 108 15 80 600.05 +0.015 0 2 x 8H7( ) depth 12 (2 x 4 x M5 x 0.8 through) For limit switch mounting C B A0.5 55 55 1000.3 Switch mounting bracket Note 2) 12 70 12 Fulcrum 13 40 15 10 F 2 x 4 x M10 x 1.5 depth 12 107 Note 3) 70 2 x 2 x 8H7 +0.015 0 ( ) depth 12 60 1 52 (58.7) (70) 95 700.05 85 75 330 270 0.3 193 (173) 133 25 100 100 (10) Rc1/ 4 Unclamp side port 306 (30.2) (30.2) 360
Cooling Capacity HRS100-A-20/40(50 Hz) HRS100-A-20/40(60 Hz) 14 14 12 12 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 40C Ambient temperature 32C Ambient temperature 40C 8 8 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature
Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
.: AN200-N02) AN600-10 270 1 1 1 AN700-12 440 1 4 AN800-14 590 1 2 AN900-20 960 2 Note) NPT thread is also available. Specify N after ANm00-.
size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250
LEKFS25(L/R)/Ball Screw Drive Horizontal Vertical 20 30 Lead 6: LEKFS25(L/R)EB Lead 6: LEKFS25(L/R)EB 25 15 Work load: W [kg] Work load: W [kg] 20 Lead 12: LEKFS25(L/R)EA 10 15 Lead 12: LEKFS25(L/R)EA 10 Lead 20: LEKFS25(L/R)EH 5 Lead 20: LEKFS25(L/R)EH 5 0 0 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] LEKFS32(L/R)/Ball Screw Drive Horizontal Vertical
Note 2) Cable O.D.: 6 to 12 mm Note 3) For an outside cable diameter of 9 to 12 mm, remove the internal parts of the rubber seal before using. Assembly 1. Insert the cable into the conduit terminal. 2.
M5 x 10 DIN913-45H VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 2 8 VT G 1/4 DIN/ISO228/1 M5 Drive flange face VP VG 19.5 5.5 Solenoid valve flange face VP O-ring 16 x 2 1.5 3 S070 VQ VKF The solenoid valve can be attached with 2 mounting bolts.
x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5 68.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 85.5 16 70.5 3.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 87.5 20.5 M6 x 1 Depth 6 32 42 3 57 52 47 127 98 115 1/2 62.5 37 80.5 M6 x 1 Depth 6 32 42 3 57 52 47 147 98 1/2 37 97.5 6 82.5 M6 x 1 Depth 6 32 42 3 57 52 47 147 98 1/2 37 99.5 10.5 06 10
Center of gravity .12 4.Product Specifications .13 4-1.Magnet Gripper .13 4-2. 3-port solenoid valve .14 4-3. Auto switch .15 5.Operating method or operation .16 5-1Precautions for Design .16 5-2. Installation .17 5-3. Air supply .22 5-4. Piping .22 5-5. Operating environment .23 5-6. Lubrication .23 6. Maintenance or inspection .23 6-1. Maintenance or inspection .23 6-2.
: 0.12 10% or less 3% or less 1MPa 12, 24VDC 0 to 2W 0 to 4W Class B Series PVQ How to Order P V Q 13 5 L 03 M5 Valve type Body materials Symbol A Nil Body Brass C37 Note for PVQ13 for PVQ31, 33 13 31 33 N.C.
4.2 M5 X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 Plug Mounting Style CJPS B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14 4.2 M5 X 0.8 M22
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.