(mm) Model Flange Note) Kv Conversion Cv Rc VND10D-6A VND10D-8A VND10D-10A VND20D-10A VND20D-15A VND30D-20A VND40D-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 0.9 1.0 1.1 4.3 4.6 8.6 13.6 1.1 1.2 1.3 5.0 5.4 9.9 16 1 8 1 4 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 25 1 1 4 1 15.7 18 32 32 1 2 1 32.9 38 40 40 2 53.6 50 62 10.8 50 Note) The companion
Symbol Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Symbol 1 K plug connector 3-7-31 Series VZS3000 How to Order Manifold Assembly Manifold Specifications Port size Rc 4(A) 2(B) Stations Porting specifications 4(A), 2(B) Port Please indicate manifold base type, corresponding valve, and option parts.
0.5 M3 x 0.5 M3 x 0.5 Effective area: 0.6 mm2 Weight: 1.6 g Effective area: 0.6 mm2 Weight: 1.4 g Nipple: M-3N Plug: M-3P Width across flats 5 Width across flats 5 M3 x 0.5 M3 x 0.5 M3 x 0.5 Weight: 0.6 g Effective area: 0.9 mm2 Weight: 0.5 g R 1/8 Series Barb Fitting for Nylon Tubing, Soft Tubing: M-01A-4/-6 Effective area (mm2) 2.1 4.0 2.1 4.0 Weight (g) 6.4 6.6 6.5 6.7 Applicable tubing
AMD Micro mist separator Nominal filtration rating: 0.01 mm Oil mist density at outlet: 0.1 mg/m3 Body size Option Symbol Flow capacity 70D 7 m3/min (ANR) 80D 11 m3/min (ANR) 90D 14.5 m3/min (ANR) Symbol Symbol Description Max. operating pressure [MPa] Nil Auto drain 1.0 H Auto drain 1.6 J Drain guide 1.6 Main line filter 1 2 Thread type Port size L * Options H and J cannot be selected simultaneously
OFF M3 hexagon screw Tightening torque 0.6 Nm 1 2 0 0 0 IP address 192.168. Y . X : Thread size: M3 x 30 The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.
Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
Solenoid on side B 1 3 5 7 9 17 29 31 No. Designation Description 1 3 5 7 1 1 5 7 Bit No.
Individual grounding should be provided close to the product with a short cable. 28 30 Hexagon socket head cap screw (M3 x 30): 2 pcs. Seal cap: (for M12 connector socket): 1 pc. Pollution degree D Side (SI unit side) NOTE Output No. 1 9 Solenoid on B side 3 5 7 17 29 31 (Note): Y connectors for external power supply are available as accessories.
Max. tightening Maximum screw-in torque depth Model Bolt Depth [mm] (Nm) JMHZ2-8 M3 x 0.5 0.88 6 JMHZ2-12 M3 x 0.5 0.88 6 JMHZ2-16 M4x0.7 2.1 8 JMHZ2-20 M5 x 0.8 4.3 10 Max. tightening Model Bolt torque Nm JMHZ2-8 M2.5x0.45 0.31 JMHZ2-12 M2.5x0.45 0.31 JMHZ2-16 M3 x 0.5 0.59 JMHZ2-20 M4x0.7 1.4 7 - ! Caution 1.
Note 3) When the compressor oil mist discharge concentration is 30 mg/m3 (ANR). 68 Series AWM20 to AWM40 Series AWD20 to AWD40 Option / Part No.
Note 3) When the compressor oil mist discharge concentration is 30 mg/m3 (ANR). 68 Series AWM20 to AWM40 Series AWD20 to AWD40 Option / Part No.
L N PE M3 6.5mm 1.25mm 2 :17 1 2 2 2 , 2 1 IDFA6E 20kg 2 2 2 2 2 1 240 050 ( ) 2000m 600mm 600mm 600mm 600mm 600mm 2 1 2 2 2 2 6 6-2 2 2 3 50 50 2 2 4 10mm ( 2 2 2 2 2 5 6-1 IEC AC200V 30mA 5A 1.25 216AWG,3 ,812 0.1m 30m M3 1.25-3 6.5mm () M3 0.61Nm 2 3 2 2 3 () 2 2 () 2 4 3 / 3 3 1 INOUT 3 2 ON () INOUT 5 ONOFF 0.15MPa NO IN 3 1 3 / 3 3 OFF OFF
M3 hexagon screw Tightening torque 0.6 Nm Terminating resistor Valve manifold : Thread size: M3 x 30 Troubleshooting The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.
15 3 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) 536 MHR3/MDHR3 Series Rotary Actuated Air Gripper 3-Finger Type With auto switch (Built-in magnet): MDHR3-15R A 3 x M3 x 0.5 thread depth 6 P.C.D.29 (Mounting thread) 21 24 MDHR3-15E Port Location 120 120 48 B 11 25 M3 x 0.5 Finger opening port M3 x 0.5 Finger closing port M3 x 0.5 Finger closing port M3 x 0.5 Finger opening
Table 3-1 Amount of heat radiation and required ventilation Required amount of ventilation [m3/min] Model No.
NSR 18 Piston seal NBR 20 Tube gasket NSA ,-External dimensions are the same as the CS2 standard type. Refer to pages 7 to 10.
When accumulated output mode is selected" on (page 31) Press the button to set. Return to function selection mode. [F 2] Setting of OUT2 complete. Output mode d. When Accumulated pulse output mode is selected There is no item to set. -39No.LFE*-OMZ0011 [F 3] Response Time The response time of the switch output can be set.
The Address assignment range is 1 to 31. The address can be set regardless of connecting order, but it is not possible to set address overlap. The address at shipment from the factory is 0.
No.PF-OMO0012-E PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2W7## Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 15 Installation 15 Piping 16 Wiring 18 Outline of setting 20 List of outputs 21 Initialize mode 22 Setting procedure
Part number of auto switchD-A9D-A9V Unitmm B A (When detecting retracted stroke end) H H 1 H 2 3 (When detecting extended stroke end) 5st 10st 15st 20st 25st 30st 35st 40st 4 6 1 6 11 16 21 26 13.0 10.0 20.0 10 1 6 11 16 21 26 31 36 41 16.0 9.5 19.0 16 1 6 11 16 21 26 31 36 41 18.0 12.0 24.0 Part number of auto switchD-M9D-M9VD-M9WD-M9WV Unitmm B A (When detecting retracted stroke end) H