Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T3 (39 L/min, CH2 Optical Head, Size 300 Only)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: 400 (CH1: 37 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Series: 7 (10-SY7000), Actuation: 2 (2 Position, Double), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: LO (L Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: 02 (1/4), Thread: N (NPT)
Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: N7 (One-touch Fitting for ø1/4")
Series: 9 (10-SY9000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: H (Grommet, Lead Wire Length, 600mm), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: N11 (One-touch Fitting for ø3/8")
Series: 9 (10-SY9000), Actuation: 2 (2 Position, Double), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: H (Grommet, Lead Wire Length, 600mm), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: N11 (One-touch Fitting for ø3/8")
Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: M [M Plug Connector, w/Lead Wire, (300mm)], Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: M5 (M5 x 0.8)
Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: N7 (One-touch Fitting for ø1/4")
Model: 3 (10-SY3000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire Length 300mm)
Model: 5 (10-SY5000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor)
Model: 5 (10-SY5000), Actuation: 2 (2 Position Double), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire Length 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4 w/Sub-plate), Thread: T (NPTF)
Model: 3 (10-SY3000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor)
Model: 5 (10-SY5000), Actuation: 1 (2 Position Single), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor)