40 20 30 27 22 5.4 8.4 40 2.3 28 115 1/4, 3/8 53 129 14 26.5 30 50 26.5 41 40 23 6.5 8 53 2.3 30 170 AF 70 165 18 35 38 75 35 50 54 26 8.5 10.5 70 2.3 35 204 1/4, 3/8, 1/2 75 169 20 35 38 75 35 50 54 25 8.5 10.5 70 2.3 34 208 3/4 AR 90 245 24 45 20 45 70 66 35 11 13 90 3.2 47 284 3/4, 1 95 258 24 47.5 20 47.5 70 66 35 11 13 90 3.2 47 297 1 AL Semi-standard specifications AW With barb
20 191 11 20 50 98 70 44.5 16 84 11 6.4 117.5 316 3.3 280 46 20 196 20 11 50 70 98 44.5 84 13 11 6.4 117.5 319 3.3 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
0.05 Slide screw 200 2 Guide rod type Series LXP 200 3 0.05 Slide screw 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 Slide table type Series LXS 200 4.5 Slide screw 0.05 100 6 Without motor brake 100 9 30 10 Ball screw 0.03
motor brake 50 Direct acting guide Series LXF 0.03 Ball screw 3 100 50 Series LXP 6 Ball bushing guide 100 Ball screw 0.03 50 5 100 Series LXS 50 10 High rigidity direct acting guide 100 Ball screw 0.03 50 5 100 5 Simplified Selection Flow Chart Series LX Standard stroke (mm) and 25 50 75 100 125 150 175 200 Model Motor Manufacturer Maximum speed (mm/s) Phases LXFH5SB LXFH5BC
One-touch fitting for 8 SUP/EXH block mounting position C8 Stations M 02 20 2 stations For 20 stations Mixed 20 stations Nil For 2 to 10 stations : One side (Same as direction of connector mount) For 11 to 20 stations: Both sides In the case of mixed specifications (M), indicate separately on the manifold specification sheet. 20 For 2 to 10 stations: Both sides Special specifications
Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.
Current consumption 10 mA or less Protection Protected against inverse connection Analogue output: 4 to 20 mA Maximum load impedance: Analogue output Output type Analogue output: 1 to 5 V Output impedance: Approx. 1 k 500 or less (at 24 VDC) 100 or less (at 12 VDC) Analogue output Accuracy (Ambient temperature at 25 oC) 2.5%F.S. Linearity 0.5%F.S. Repeatability 0.5%F.S.
In case of 2000 mm of lead wire For DC For AC VEX3122-015LO1 VEX3122-011LO1 SY100-30-4A-20 SY100-30-1A-20 Connector Assembly with Cover Connector assembly with dust proof protective cover. Effective to prevention of short circuit failure due to the entry of foreign matter into the connector.
4 Pneumatic type (non-lube) Piston seal Rod seal NBR CQ2B12-PS 12 16 20 25 32 40 50 63 80 100 CQ2B12-PS CQ2B16-PS CQ2B20-PS CQ2B25-PS CQ2B32-PS CQ2B40-PS CQ2B50-PS CQ2B63-PS CQ2B80-PS CQ2B100-PS CQ2B16-PS Gasket CQ2B20-PS CQ2B25-PS CQ2B32-PS Set of left nos. !2, !3, !4.
4 Pneumatic type (non-lube) Piston seal Rod seal NBR CQ2B12-PS 12 16 20 25 32 40 50 63 80 100 CQ2B12-PS CQ2B16-PS CQ2B20-PS CQ2B25-PS CQ2B32-PS CQ2B40-PS CQ2B50-PS CQ2B63-PS CQ2B80-PS CQ2B100-PS CQ2B16-PS Gasket CQ2B20-PS CQ2B25-PS CQ2B32-PS Set of left nos. !2, !3, !4.
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
Positioning complete signal 19 OZ+ Z Z 10 20 COIN OZ+ 14 GND VDC 12 to 24V 13 4.7k COM Torque monitor: Zout 4.7k 12 + IM VDD 30V max. 15mA max. 11 Speed monitor: Zout 4.7k 4.7k SP + 21 CZ Z (Pin 14 is GND.) 26 FG CN I/F 205 Non-standard Motor Compatible Drivers Mitsubishi Electric Corporation Drivers for LJ1, LG1, LX Dimensions (RS-232C without optional unit) Driver 5 100 40 1-5 hole 5
Pressure range Rated pressure Characters displayed on the sub display Vacuum pressure -101.0 kPa Compound pressure 100 kPa Positive pressure 1 MPa Table showing the output mode and output form when Md1 and Md2 are selected.
Max. 100 mm (MACM10-50) 100 50 (Stroke) Table center Right/left Table centering accuracy 1 mm or less (Workpiece not loaded) Rotation Forward/backward Angled 3 types of table material can be selected.
Type Symbol sensor Flow rate Flow rate Temp. 1 Analogue 1 to 5 V None 2 Analogue 4 to 20 mA Remote sensor 1T Analogue 1 to 5 V Analogue 1 to 5 V With temp. sensor 2T 1 Analogue 4 to 20 mA Analogue 4 to 20 mA A NPN NPN B PNP PNP C NPN Analogue 1 to 5 V D NPN Analogue 4 to 20 mA None E PNP Analogue 1 to 5 V F PNP Analogue 4 to 20 mA G 1 NPN External input 2 Integrated display type H 1 PNP External
(guideline) Command 2400bps 19200bps 57600bps EE 145 25 10 EU 105 20 10 AB 105 20 10 MO 245 35 15 MD 115 20 10 OE 130 20 10 Calculation Example) Number of controllers connected: 5 Required transmission commands: EE,EU, AB Communication response time ( 25 + 20 + 20 ) x 5 = 325 ms Response time (guidline) 500 450 400 Response time [ms] EE 350 EU,AB,MD,OE 300 MO 250 200 150 100 50 0 1 2 3 4
kPa 100 kPa 01 MPa 0 1 MPa -0.1 MPa 0500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0005CN-E PSE5601 PSE56N01 02 N02 PSE56-C01 A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 ZS-31-X D E F G H I ZS-31-X188 20 9 R1/8 R1/8 14 1.5 ZS-31-X189 20 9 NPT1/8 NPT1/8 14 1.5 ZS-31-X175 29 13 R1/4
No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12
ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3.
Load factor 50 100 mm Operating pressure 0.5MPa The length of Brake releasing pressure 0.3MPa 50 No load overrun Mounting position Horizontal 0.5 1.0 Piston speed just before stop ms 11-2 Dispersion of stopping position When cylinder is stopped intermediately, the stopping position is not fixed.