[F80] Power saving mode completed In power saving mode, when buttons are pressed the display is normal, but if no buttons are pressed for 30 seconds, it will revert to power saving mode.
HECR008-W HECR012-W 1 Unused BUS + 0 0 Operation temp. range 10.0 to 60.0 C (No dew condensation) 5 4 3 2 1 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 During operation or maintenance of the product, do not disable the Communication Indication temp. range -9.9 to 80.0 C 2 RXD (RD) Unused Circulating fluid temp. deg.C Circulating fluid temp. deg.C connector Temp: 10 to 35 C Humidity : 35
LEY40#EA: 9 kg, LEY40#EB:19 kg, LEY40#EC:38 kg LEYG40#EA:7 kg, LEYG40#EB:17 kg, LEYG40#EC:36 kg 10 mm minimum Door (Lid) 30 mm minimum Controller 60 mm minimum 30 mm minimum (direct mounting) 50mm or more (DIN rail mounting) Controller Caution If the mounting surface for the controller is not flat or is uneven, excessive stress may be applied to the enclosure, which can cause failure.
15.0 11.5 23.0 10 5 10 15 20 25 30 35 40 45 18.0 10.5 21.0 16 5 10 15 20 25 30 35 40 45 20.0 13.0 26.0 * The above numbers are references for the mounting positions of those auto switches that detect a stroke end.
How to Order Connector Assembly For DC SY100-30-4AFor 100 VAC SY100-30-1AFor 200 VAC SY100-30-2AFor other voltages of AC SY100-30-3AWithout lead wire SY100-30-A (with connector and 2 of sockets only) How to Order Include the connector assembly part number together with the part number for the plug connectors solenoid valve without connector. Ex.)
(deg) 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to 9 1/2 15 to 30 14 to 15 Air Supply 1. Use clean air 2) The gasket can be reused up to 6 to 10 times. It can be replaced easily when it has sustained damage. A broken gasket can be removed by holding it and then turning it in the same direction as loosening the thread. If the gasket is difficult to remove, cut it with nippers, etc.
Construction/Replacement Parts 30 6.1. Construction for Single Unit 30 6.2. Component Parts 30 6.3. Replacement Parts 31 6.4. Replacement Parts for Single Unit/How to Order 31 7. Exploded View of Manifold/Replacement Parts 35 7.1. Exploded View of Manifold 35 7.2. How to Increase Manifold Stations 35 7.3. Component Parts 38 7.4. Replacement Parts 38 7.5.
Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
17.5 NPT 3/8 35.5 41.8 49.6 55.6 30 22.2 NPT 1/2 37.6 45.8 49.6 55.6 30 15-13-4
1 4 3 8 30 30.5 17 KAT10-U02 KAT10-U03 26.5 18.5 17 10 21 29.0 29.0 1 2 KAT10-U04 30 31.5 51 31 34 22 1 4 3 8 27 28 31.5 32.5 KAT12-U02 KAT12-U03 17 20.9 17 12 28.5 22 45.2 45.2 1 2 KAT12-U04 31 33.5 22 54 Reference dimensions after Uni thread installation.
Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 Mounting 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 Mounting 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
Open the inner package of double packaging in a clean room or other clean environment. 12 to 14 R 1/4 22 to 24 R 3/8 28 to 30 R 1/2 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
L dimension 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 VZ VS VFN Silencer (For manifold EXH port) Silencer is installed in the EXH port. 63 38 22 Dimensions 13 Silencer part no.
5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 1-1/4" 32 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.
Free Mount Cylinder Double Acting, Single Rod Series CU 6, 10, 16, 20, 25, 32 How to Order CU 6 30 D 30 6 30 M9BW CDU With auto switch D Made to order Refer to page 484 for the Made to Order specifications. Built-in magnet Number of auto switches Bore size 2 pcs. 1 pc.
Connecting Female Thread: G Approx. spanner tightening angle after tightened by hand deg Standard torque (Nm) Nominal size of uni thread 1 8 1 4 3 8 1 2 30 to 45 15 to 30 15 to 30 15 to 30 3 to 4 4 to 5 8 to 9 14 to 15 2. Gasket can be recycled 6 to 10 times. It can be replaced easily when it has sustained damage.
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).