Rated Pressure Range: -100 to 100 kPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -

Rated Pressure Range: 1 to -101 kPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -

Flow Adjustment Valve: With Valve, Port Size: Rc1/4, Piping Entry Direction: Bottom, Output Specifications: NPN, NPN, Option 1: w/Lead Wire w/Connector + Connector Cover, Unit Specifications: Unit Selection Function, Option 2: With Panel Mount Adapter, Calibration Certificate: -

Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: No Operation Manual; No Calibration Certificate, X Options: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/Flow Adjustment Valve

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/Flow

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.  Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount