Series: 5 (VFA5000), Actuation: 1 (2 Position Single), Body: 20, A, B Port Size: 03 (3/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Accuracy: Basic Type, Size: 32, Motor Mounting Position: D (In-line), Motor Type: NT (Mounting Type T), Lead Screw: A [LEY25, 12mm; LEY32, 16mm, (20); LEY63, 20mm], Stroke: 150mm
Accuracy: Basic Type, Size: 63, Motor Mounting Position: D (In-line), Motor Type: NT (Mounting Type T), Lead Screw: A [LEY25, 12mm; LEY32, 16mm, (20); LEY63, 20mm], Stroke: 200mm
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C+L, Option 2: T (Terminal Block for Run & Alarm Signal)
Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C+L, Option 2: T (Terminal Block for Run & Alarm Signal)
Material: S (Body: Stainless Steel 304; Gasket/O-ring: NBR), Element Length: A (ℓ250), Port Size R: 20 (2), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 20 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only
Solenoid Direction: S (Same Side of A Port), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 20, Port Size: 01 (Rc 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Thread: T (NPTF)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: E3 (Output: PNP output / Electrical entry: Wiring bottom entry), Attachment: T (T spacer), Semi-Standard 1: Standard, Semi-Standard 2: ZA (Digital Pressure Switch: With Unit Conversion Function)
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 20 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket), Made to Order: X77 (Differential Pressure Indicator)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 6 (12VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 6 (12VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 6 (12VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Valve Mounting Direction: Solenoid on the Side Opposite to A Port, Piping: 42R (Base Mounted), Stations: 20 Stations, A Port Size: N3 (5/32" One-touch Fitting), P R Port Thread: T (NPTF)
Valve Mounting Direction: S (Solenoid on Same Side as A Port), Piping: 42R (Base Mounted), Stations: 20 Stations, A Port Size: N3 (5/32" One-touch Fitting), P R Port Thread: T (NPTF)