FMW-4200-X4W .5" WC 4" WC 10 0.5" WC 1.2" WC 3A FMW-4200-X5-10 .2 5 30 .5 .8 10A FMW-4200-X5 .5 5 30 .5 .8 15A FMW-4200-X10 .5 5 30 1.0 1.5 15A FMW-4200-X30 1.5 30 30 2.0 3.0 15A Ordering Information Stocked
one piece) E3 03 R S AMR 4 0 00 02 E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM Model Port size (Rc) Rated flow rate (L/min) Model/Rated Flow Rate FH FH FH150-02 FH150-03 FH150-04 5 1/4 HOW 10 3/8 20 1/2 Description Part no.
Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.
Click here for details Port size (Rc) 06 08 10 12 16 20 24 3/4 1 1 1/4 1 1/2 2 2 1/2 3 Differential pressure indication Nominal filtration 0 4 5 005 010 020 074 105 5 m 10 m 20 m 74 m 105 m None Differential pressure indicator Differential pressure indication switch Note) Note) N.C. and N.O. common Note) The paper elements for water-glycol or emulsion is 10 m only.
Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action Port size Lubrication Model Rubber Air 10-MGF40 10-MGF63 10-MGF100 1/8 Relief type (Both sides) Double acting 30, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.
Port size Lubrication Model Rubber Air 10-MGF40 10-MGF63 10-MGF100 1/8 Relief type (Both sides) Double acting 30, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.
MXU MXS + MXQ MXF
Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.
Alternately, the PF3W3 panel mounted flow monitor is available for machines without an HMI. PF3W5-Z is IP65 rated, and is both RoHS and CE compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.
Flow ranges (L/min): 0.5-4, 2-16, 5-40; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4 (flow range dependent); Temperature rating: 0-90°C; Output options: IO-Link, PNP/NPN, 1-5V, 4-20mA; Accuracy: ±3% F.S. (display, analog out); ±5% F.S. (temperature sensor); Repeatability: ±2% F.S.
Alternately, the PF3W3 panel mounted flow monitor is available for machines without an HMI. PF3W5-Z is IP65 rated, and is both RoHS and CE compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.
The device includes an error status LED. This is a grease-free product. Flow ranges (lpm): 0.5-4.0, 2.0-16.0; Port sizes (Rc): 3/8, 1/2; Operating pressure (MPa): 0.2-0.4; Power supply: 24 VDC; I/O signals: 1 to 5 VDC [IN] / variable frequency pulse [OUT]; Accuracy: ±5%F.S.; Response time: ≤10s
Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.
Flow ranges (L/min): 0.5-4, 2-16, 5-40; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4 (flow range dependent); Temperature rating: 0-90°C; Output options: IO-Link, PNP/NPN, 1-5V, 4-20mA; Accuracy: ±3% F.S. (display, analog out); ±5% F.S. (temperature sensor); Repeatability: ±2% F.S.
Basic Foot Front flange Double cleivis JT2Ql10 SCJ210, #1 SCJ210, #1, #3 SCJ210, #1, #9 SCJ210, #5 JT2Ql16 SCJ216, #1 SCJ216, #1, #3 SCJ216, #1, #9 SCJ216, #5 * The data shows auto switch equipped styles. Please delete the unnecessary parts. 1.3-55
Refer to pages 13-15-3 to 13-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 13-1-5 for Precautions on every series. Handling of One-touch Fittings Mounting Caution Caution Connection and disconnection of the tube with Onetouch fitting 1. Installing of the tube 1) Cut the tubing at a right angle.
Microprocessor-Controlled Electro-Pneumatic Regulator ITV2000 EASY PROGRAMMING GUIDE MICROPROCESSOR-CONTROLLED E-P REGULATOR CONTENTS: ITV2000 1. LAYOUT IDENTIFICATION, 2 2. WIRING, 2 3. INPUT SIGNAL, 3 4. KEY LOCK FUNCTION, 3 5. SET POINT PROGRAMMING, 4 6. ADJUSTING MINIMUM & MAXIMUM PRESSURES, 5 7. MONITOR OUTPUT, 5 8. ERROR MESSAGES, 6 9.
81 11 M6 x 0.75 10 5 1 6.5 15 123 +0.08 0 32 5.5 10 M10 x 1.25 15 35.5 1/8 11 81 11 M8 x 1.0 12 5.5 1 7.5 24 123 +0.08 0 40 6 14 M14 x 1.5 19 44 1/8 11 92 12 M10 x 1.25 14 6 1.25 8.5 24 144 +0.08 0 50 +0.08 0 7 18 M18 x 1.5 19 55 1/4 11 107 13 M12 x 1.25 16 7.5 2 10 24 167 63 7 18 M18 x 1.5 19 69 1/4 11 107 13 M14 x 1.5 18 11.5 3 14.5 24 167 +0.08 0 80 10 22 M22 x 1.5 23 80 3/8 21 130 40