8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 8 12 9.5 11 10 8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 CHM CHS CH2 CH2 CHA CH2F (mm) Auto switch model Bore size (mm) 32 Related Products 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59/F59F
Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14 22 22
TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.
One-touch fitting 06 08 10 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting Power supply cable Refer to the table below for selection of One-touch fittings.
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80
11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12.5 16.5 23.5 23.5 Bracket Combinations Bracket combination table -Refer to table together with combination drawings.
Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.
Composed effective area So (mm2) 6 2000 h=0.7 10 1/4, 3/8 7.5 2500 REC 0.5 10 10 1/4, 3/8 0.1 0.3 9 3000 RHC 6 1/4, 3/8 2.5 500 8 1/4, 3/8 MTS 5 1000 0 1,000 2,000 3,000 25 (1/4) 10 1/4, 3/8 Max. speed Vmax (mm/s) 7.5 1500 CC Graph 3:32 10 1/4 10 2000 12.5 15 2500 3000 30 1/4 1/4 h=0.7 6 10 1/4, 3/8 20 4 500 0.5 0.1 0.3 10 32 (3/8) 10 1/4, 3/8 8 1000 0 1/4, 3/8 3/8 3/8 3/8 12 16 20 24 1500
4 88 116 5 107 135 6 126 154 7 145 173 8 164 192 9 183 211 10 202 230 Symbol L1 L2 4-15-17 18 Series VZ200/400 Precaution 1 Be sure to read before handling.
5 2.86 20 10 5 Parameter *1,*2 Para.
Air Fluid Operating pressure range (MPa) 0.15 to 0.7 Internal pilot Ambient and fluid temperature (C) Response time (ms) (at the pressure of 0.5 MPa) (1) 10 to 50 (No freezing. Refer to page 4-18-4.) 20 or less Max. operating frequency (Hz) 10 Flow characteristics Refer to the table below.
B C D H SNKJ-016B SNLJ-016B SN-020B SN-032B NTJ-010A NTJ-015A NT-02 NT-03 19.6 M12 x 1 4 8.1 M4 x 0.7 3.2 6, 10 17 6, 10 7 21.9 M14 x 1 5 9.2 M5 x 0.8 4 16 19 16 8 30 M20 x 1.5 8 15 M8 x 1.25 5 20 26 20 13 37 M26 x 1.5 8 19.6 M10 x 1.25 6 25 32 25 17 T-bracket 4-TC TH 7 +0.2 0 TU -0.1 -0.3 TN TK TX TV 12 TD H10 TT TY TW Part no.
to 50C 10 to 50C Ambient and fluid temp.