Do not disassemble the product. Once the product is disassembled and reassembled, it will not be able to satisfy the original performance. 4. When piping, do not get the pad side and vacuum generator side of the product the wrong way round. (Refer to Fig. 1.)
Do not drop, hit or apply excessive shock to the product. Even if the body is not damaged, the internal components may be damaged, leading to a malfunction. Wiring/Piping Warning 1. Power supply required to the product is 24 VDC and 1 A.
Do not make any upward angles in drain line.
Do not use this aftercooler in an area that has viscous dust (electrostatic paint powder, oily particles, etc.). If it must be used under such conditions due to unavoidable circumstances, please contact SMC beforehand.
Do not allow the weight of piping to be applied directly to the air dryer. HA AT ID Avoid installation on moving objects like trucks, ships, and so forth. Drain Tube AMG Caution AFF A polyurethane tube of 10mm outer diameter is provided as the drain tube for IDFS6E to 11E and IDUS3E to 6E. Use this tube to discharge drainage. Do not use the drain tube in an upward direction.
Free mounting Speed controllers do not protrude from the top of the body. Top mounting Bottom mounting Side mounting Wiring and piping direction can be selected depending on mounting conditions.
Therefore, do not touch its exterior surface because it could be very hot, depending on the energizing conditions.
Do not scratch or gouge the piston rod of the actuating cylinder, as this could damage the rod seal and lead to air leaks. The same applies to the guide shaft. 3. Make sure not to apply shocks or excessive moment to the slide block of the ball bushing type. 4.
Note) When using the D-M9A(V), do not use the steel set screws which are included with the auto switch mounting brackets above (BMB10-032, BMB5-032, BA7-040, BA7-063).
Do not scratch or gouge the sliding portion of the piston rod. Damaged seals etc. will result in leakage or malfunction. 4. Do not dent or scratch the mounting surface of the body and the plate. The flatness of the mounting surface may not be maintained, which would cause an increase in sliding resistance. 5.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
system Natural air cooling Operating temperature range 0C to 40C (No freezing) Operating humidity range 90% RH or less (No condensation) Storage temperature range 10C to 60C (No freezing) Storage humidity range 90% RH or less (No condensation) Insulation resistance Between all external terminals and the case: 50 MW (500 VDC) Weight 1050 g (Screw mounting), 1100 g (DIN rail mounting) *1 Do
" 0.006 8.3 Note 2) Rotating torque under pressure 0.5 MPa Note 3) Do not use the fittings with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.
Gripping fingers do not scrape the tube during insertion or removal. 2. Body SMCs composite body offers: 1. Weight savings 2. Compact dimensions 3. High performance 4. Superior chemical resistance 2. Lower insertion and release forces. 7.
As the connected actuator will start operating due to this manual operation, be sure to confirm that it is safe to do so beforehand. Ex. 1) Cable length: 300 mm DXT1215T-5W1U-01m(-X1) Symbol for electrical entry MNon-locking push type Push the manual override button all the way down. 2.
When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc. When washing the element, do not wipe it using a stiff brush or rag. Refer to page 529 for Microswitch for differential pressure indication switch. r Removing the element Rotate the air breather (cap) one-third of a turn counterclockwise and remove it.
Please do the vacuum aspiration according to customer's specification.
Please do the vacuum aspiration according to customer's specification.
Do not bring objects that are sensitive to magnetism near the cylinder. The magnet is built into the cylinder. Do not bring magnetic disks, cards or tapes near the cylinder. Data may be lost. 5. If the cylinder is operated vertically with heavy loads, measures must be taken to prevent rapid extension of the piston rod when starting to operate in the downward direction.