SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-41-10-01T"

Allowable voltage fluctuation is 10% of the rated voltage.

Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid

D-F8 type auto switches are only applicable to 8 cylinders. 1 Precision Cylinder Series MTS Specifications 8 10 12 6 16 8 25 20 13 32 16 40 Bore size (mm) Spline rod size (mm) 4 20 Fluid Air 0.1MPa Without end lock 0.15MPa 0.12MPa Min. operating pressure With end lock 0.15MPa 0.17MPa Maximum operating pressure 0.7MPa Proof pressure 1.0MPa Ambient and fluid temperature 10 to 60C (with no

Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No.

) Note 10) Note 10) Note 10) Note 10) Note 10) use pressure within the specification range.

DC(+) (OUT) 2 OUT2// 3 DC(-) 4 OUT1 (IN) M8 M8 IN OUT (UP) (SET) (DOWN) () OUT1OUT2 ON (1 ) (UP) ON/OFF (SET) (DOWN) ON/OFF -11No.PF-OMS0001CN-A F.S. ( 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF () (0100)() 90 () (0100) ()90ON(OFF) 0 1 atm()[nor] () 10 L/min 10 L ON OFF ON OFF 0 -12No.PF-OMS0001CN-A , , 2 5 10 L/min 5 ,51050 L ON-OFF () 1 L

Bellows assembly (7) XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No. Bellows assembly (7) XL1A63-2-101 XL1A80-2-101 Nut assembly (9) XL1A50-10-1 XL1A80-10-1 Note 1) Bellows assembly contains the valve seal 1. It does not contain the valve seal 2.

Series 10 12 16 20 25 32 40 50 63 80 100 MHZ2 3.0 5.0 7.0 7.0 8.0 8.5 MHZL2 6.0 7.0 10.0 11.0 MHL2 7.0 8.0 8.5 10.5 11.0 12.5 MHS2 6.5 7.0 7.5 8.5 MHS3, MHS(L)3 6.5 7.0 7.5 8.0 MHS4 6.5 7.0 7.5 8.5 MHC2 30 to -10 30 to 30 to 22.5 to -10 -10 -10 MHW2 88 to 54 to 58 to 41 to 30 to -4 -5 -6 -5 -5 Air cylinder Unit: mm Tube I.D.

Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.

Model selection PsAllowable pressure Refer to page 21, Table 10 PsAllowable pressure Refer to page 21, Table.10 Es Allowable kinetic energy Refer to page 21, Table 10 13/28 In this series, the work load and the maximum operating pressure are restricted to prevent the magnetic coupling from being separated.

Assembly and disassembly of the SI unit -35No.EX-OMP0013-E Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Pollution

PSE531 PSE541 PSE561 Applicable pressure sensor PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) 5%R.D.

The voltage variation must stay within the 10% to +10% range of the rated voltage. In case importance is attached to response characteristics due to use of a DC power source, keep the variation within the 5% to +5% range. The voltage drop is the value at the lead wire to which the coil is connected.

Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).

to 10 30 to 10 22.5 to 10 180 Angular style MHW2 88 to 5 54 to 6 58 to 5 41 to 5 30 to 4 Air Cylinders (mm) Description/Series Bore size 10 12 16 20 25 32 40 50 63 80 100 Compact guide cylinder MGP 3.5 5.0 4.5 4.5 5.5 5.5 5.5 5.5 5.5 6.0 Non-rotating double power cylinder MGZ 5.5 6.5 6.5 Air cylinder CA2 4.0 4.0 6.0 6.0 6.0 Sensor Unit D-F7K Air Cylinders (mm) Description/Series Bore

Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.

64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 7