Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4"), Accessories: NS (w/o Standard Bracket, w/Silencer)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4")
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4")
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4"), Accessories: S (w/Standard Bracket, w/Silencer)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4"), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 07 (One-touch Fitting ø1/4"), VAC: 07 (One-touch Fitting ø1/4"), EXH: 07 (One-touch Fitting ø1/4"), Accessories: N (w/o Bracket, w/o Silencer)
) 03 (3, 1/8"), 04 (4), 06 (6), 07 (1/4") only Table 1 Tubing Size Symbol Metric size Inch size Tubing O.D. 3 03 4 04 6 06 8 08 10 10 12 12 19 19 25 25 1/8" 03 1/4" 07 3/8" 11 1/2" 13 3/4" 19 1" 25 Symbol Note 1) GPS GB GB GPS Fitting type Note 1) Sizes with the same symbol number and 06 and 07 are common sizes. 6 c Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 505 Applicable Fluids Material and fluid compatibility check list for High
GW unit Gateway distribution system 2 (128 points) Gateway distribution system (64 points) EX500-GEN2 EX500-GPN2 EX500-GDN1 EX500-GPR1A Gateway distribution system 2 (128 points) Usable Usable :Same specifications of gateway EX500-S103 EX500-DXP# distribution system (64 point) SI unit Input unit Gateway distribution system (64 points) Usable EX500-S001 EX500-Q#01 EEX500-IB1-# Usable :Same
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-29No.EX-OMV0023-A (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).
Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-28No.EX-OMN0011-F (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-34No.EX-OMO0030-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32
How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.
Rated pressure range A B ZSE3 0 to -101 kPa 0 -101 kPa ISE3L 0 to 98 kPa 0 98 kPa ISE3 0 to 0.98 MPa 0 0.98 MPa -25No.PS-OMO0002-A Dimensions Grommet type Z/ISE3-01/T1-26No.PS-OMO0002-A Connector type Z/ISE3-01/T1-C -27No.PS-OMO0002-A Single-installation type Grommet type ZSE3-0X-28No.PS-OMO0002-A ZSE3-0X--D -29No.PS-OMO0002-A Connector type ZSE3-0X-C -30No.PS-OMO0002-A ZSE3-0X-C-D -31No.PS-OMO0002
SQ2000 20 ms or less Cylinder Speed Chart Pressure: 0.5 MPa/Load factor: 50% Flow Characteristics Note) Series CJ2 6 10 16 20 25 32 40 Series CM2 Bore size (mm) Base mounted Average speed (mm/s) Metal seal Rubber seal C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 800 700 600 500 400 300 200 100 0 Perpendicular, Upward actuation Horizontal actuation SQ1000 0.63 0.11 0.14 0.80 0.20 0.19 800 700
Note Panel mount adapter Waterproof seal, screws included ZS-26-B Front protective cover ZS-26-01 Front protective cover + Panel mount adapter Waterproof seal, screws included ZS-26-C ZS-26-D 48 conversion adapter 48 conversion adapter This adapter is used to mount Series PSE200 on the panel fitting of Series PS100. Order panel mount adapter separately.
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.