The right side of the common port provides plug. 4.1-65 VVXA21/22 Dimensions Common SUP style Individual SUP style L: Dimensions Model Stations 2 3 4 5 6 7 8 9 10 L L1 L2 L1 L2 100 86 126 108 136 122 172 154 172 158 218 200 208 194 264 246 244 230 310 292 280 266 356 338 316 302 402 384 352 338 448 430 388 374 494 476 VVXA21m VVXA22m Model VVXA21m VVXA22m A 38 49 B 20.5 [17.5] 26.5 [22.5]
mm/s or less Base Mounted SY SY Body Ported 300 mm/s or less S0700 Base Mounted S0700 S0700 Body Ported 500 mm/s or less Base Mounted [Common conditions] Pressure: 0.5 MPa Piping length: 1 m Load ratio: 50% Stroke: 200 mm Use as a guide for selection.
Solenoid Specifications 100, 200 VAC, 50/60 Hz; 24 VDC Coil rated voltage How to Calculate the Flow Rate 15 to +10% of rated voltage Allowable voltage fluctuation For obtaining the flow rate, refer to page 31-10.
rate (l/min (ANR)) 1.5 3 6 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 07, 08, 09, 10, 11 Effective area (mm2) Effective area (mm2) Effective area (mm2) 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 14 Flow rate (l/min (ANR)) 20 Flow rate (l/min (ANR)) 10,11 12
Standard stroke -X Bore size (mm) Standard stroke (mm) Piping port location 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h 20Nil Note 1) Please consult
VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134
Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders. Conrm that the combination of the controller/driver and the actuator is correct.
5.0 MPa Pilot Operated 2 Port Solenoid Valve Series VCH40 How to Order Valve type 1 D G VCH4 1 06 Voltage N.C. 1 2 3 4 5 6 100 VAC 200 VAC Thread type (Conforming to ISO1179-1 on the pneumatic/hydraulic G thread) 110 VAC 220 VAC 1 24 VDC Port size 2(OUT) 1(IN) 12 VDC 06 10 3/4 Consult with SMC for other voltages. CE marking compliant products are only available with 50 VDC or less.
(Example) For 6 stations 06 How to Order (Single unit) ZFA 100 01 Bracket Air suction filter Symbol Nil L None Bracket 1 pc. on the left R LR ZFA100 Body type 1 pc. on the right With both the left and right sides 100 Filtration area (mm2) Symbol L or R shows the left or right of the filter IN when viewed from front. 2110 4210 200 Port size Thread type 02 01 Port size Applicable model Symbol
ID205 to 605 / 206 to 606 (200/220V specified) Remove the terminal block cover or the rear cover in the rear of the product, and connect the power (200/220V AC) to the terminal block. Please install it on either of the M4 screws of the IN/OUT piping when you put up the earth. IN OUT Specification of power cable The following power cable is attached.
Socket with check valve 300 KKA4: Plug and socket with check valve on both sides Insertion force [N] 200 100 KKA3: Plug without check valve.
Compact Cylinder/Standard Type: Double Acting, Double Rod Construction Series CQ2W 12, 16, 20 25, 32, 40 50, 63, 80 100 Replacement Procedure is P.290 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !1 !3 !2 !1 !3 !
100 200 205 Inch size M5 standard 1/8 standard 1/4 standard 3.2 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" 4 6 8 Use a 1/8" tube.
The load voltage is 100 or 200 VAC. A contact protection box should be used in any of the above conditions, Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.) D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length.
Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Series ZL112/212 Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage performance Maximum suction flow rate l/min (ANR) Air consumption l/min (ANR) Vacuum pressure Q1 Q2 Q3 ZL112 100 200 ZL212 63 126 Q1 Q2 Q3
Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid
N 200 N Torque resistance 7.5 Nm (0.5 MPa) 7.5 Nm (0.5 MPa) Moment resistance M 3 Nm 3 Nm 7.5 Nm (0.5 MPa) 30 Nm (0.5 MPa) Torque resistance T 3 Nm 12 Nm 0.7 MPa Max. operating pressure 100 kPa or more (10 Torr or more) Operating vacuum pressure Air Electricity Interface 0.072 Cv value 6 Number of circuits 2 A/interface Contact point capacity 12 Number of contact points Values given on
/cycle (Standard) Operating time Power source 100, 200 VAC Hz, Other 4 W IN: Rc , OUT: Rc 550 g 50 60 Power consumption 3 8 1 2 Port size 3 8 Weight If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute. Precautions the tank. Failure to observe this precaution could lead to malfunctions. 2.
JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 AS-F 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 TMH 400 200 06, 07 02 01, 23 ASD 300 50 03, 04 100 200 AS 01, 23 100 AS-FE 0 0 0 KE 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations AS-FG AS-FG Note) -U10/32 has the same specification