SMC Corporation of America
Elite Part Number Search
Search Results "PF3W540-N04-1T-A"

Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Size of Body: 40, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.7 MPa, Drain Outlet: N/A,

Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Size of Body: 40, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.7 MPa, Drain Outlet: N/A,

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time. 

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate:

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None,

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog