Work piece mounting reference plane Rc 1/4 Vacuum suction port Rc 1/4 Vacuum suction port 80 Stroke + 115 (table movement range) 7.5 194 (249) 41 46 58 2-T-slot 1 57 65 69 90 95 9.3 44 40 (T-slot pitch) 2-T-slot 2 Stroke + 350 (405) 17 28 23 (78) 40 36 Body mounting reference plane 3-5H10 depth 5 3.3 5.8 1.7 5.3 T-slot 1 dimensions (switch groove) 11.5 45 27 (82) 40 80 Stroke + 145 9.4 4.5
1/4 ( ): In the case of Rc 1/4 02 03 02 03 02 03 3 position closed center: VFRA33113 position exhaust center: VFRA34113 position pressure center: VFRA3511(Pilot port) 2-Rc 1/8 (Pilot port) Main valve manual override (Direct manual) (Mounting hole) ( ): In the case of Rc 1/4 5-3-21 4 5 Port Air Operated Valve Series VFRA4000 How to Order 03 VFRA4 11 2 Thread type (Including pilot port) Function
1/2 14 PA P 14 PA 80.5 4-1/8 12, 14 port R1 R1 67 L1 = 56n + 90 L2 = 56n + 106 40 (41.5) 38 (27) Rc 3/4 1 3 5 SMC Dimensions inside ( ) are for Rc 3/4.
1/8 NPT 1/8 G 1/8 49.5 60 7 7 4.5 10 12 34 5.5 9 23 10 30 10 to 50, 75, 100 60.5 M8 x 1.25 M6 x 1.0 48.5 13 16 (15.8) 52 8.5 Rc 1/8 NPT 1/8 G 1/8 57 69 7 10 5 14 12 40 5.5 9 26 10 40 10 to 50, 75, 100 62 M8 x 1.25 M8 x 1.25 50 13 16 (15.8) 64 12 Rc 1/4 NPT 1/4 G 1/4 71 86 8 10 7 14 12 50 6.6 11 26 14 Note) ( ): Rod end dimensions With rod end male thread: MQQ-DM Rod end nut H1 (mm) Bore
1/8 NPT 1/8 G 1/8 7.5 10.5 G 1/8 Rc 1/8 NPT 1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc 1/8 NPT 1/8 G 1/8 8 11 G 1/8 56.5 39.5 8 11 52 50 41.4 Rc 1/8 NPT 1/8 75, 100 56.5 39.5 10 to 50 50.5 30.5 50 10.5 10.5 Rc 1/4 NPT 1/4 G 1/4 60.5 40.5 10.5 10.5 64 62 53.4 Rc 1/4 NPT 1/4 G 1/4 75, 100 60.5 40.5 Bore size (mm) 32 40 50 V W HA OA HB IA IB J KA KB L M N OB RA RB Z +0.2 0 38 10 5 60 58.5 4.5
Port thread type M thread Rc NPT G 8 to 16 Nil Number of auto switches Nil TN TF 20, 25 2 pcs. 1 pc. n pcs.
ALBA90-10 ALBA90-20 ALBA90-30 Bypass lubrication adapter Standard accessory Rc Ball valve 1 4 VE Ball valve 1 2 Rc VY1 IS440-1 (Without oil ON) IS440-2 (Without oil OFF) Note) Float switch Option The condition of the generation of micromist can be checked from the oil filler port.
Rc 1/8 7 to 9 Rc 1/4 12 to 14 Rc 3/8 22 to 24 Rc 1/2 28 to 30 Rc 3/4 28 to 30 Rc 1 36 to 38 Rc 11/4 40 to 42 Rc 11/2 48 to 50 Rc 2 48 to 50 Reference How to tighten M5 threads on the fittings After tightening by hand, use a tightening tool to add about 1/6 turn more. But when using miniature fittings, after tightening by hand, use a tightening tool to add 1/4 turn more.
S Stainless steel body Nil F N T Nil B Rc G NPT NPTF None With bracket (VN-16) is valve size L Aluminum body Refer to Table (1) on page 17-2-13 for availability. Valve size: 2 to 7 Threaded port only Valve size 1 comes with VN1-A16 (with thread). Shipped after assembled at our factory.
Proper tightening torque N m Tightening torque for piping Connection threads Rc 1/8 7 to 9 Rc 1/4 12 to 14 Rc 3/8 22 to 24 Rc 1/2 28 to 30 Rc 3/4 28 to 30 5. Connection of piping to products When connecting piping to a product, avoid mistakes regarding the supply port, etc. 13 Series VCA 2 Port Solenoid Valve for Fluid Control Precautions 3 Be sure to read before handling.
1/4 Common SUP. port ZF ZP 2-M5 x 0.8 Common pilot EXH. port ZCU Rc 1/8 Individual SUP. port AMJ Misc.
1/8 Rc 1/4 One-touch fitting for 6 One-touch fitting for 6 Rc 1/8 Rc 1/4 01 02 C6 C8 One-touch fitting for 6 One-touch fitting for 6 01 02 C6 C8 Name plate N Note) When two or more symbols are specified, indicate them alphabetically.
1/8 Rc 1/4 Rc 1/8 Rc 1/4 01 02 C6 C8 DIN rail mounting style (For manifold) D One-touch fitting for 6 One-touch fitting for 8 F With bracket N Name plate Manifold Note) Drop prevention Intermediate stops When two or more symbols are specified, indicate them alphabetically.
100 75 50 25 0 0 0 500 1500 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AW20(K) Rc 1/4 AW40(K) Rc 1/2 AW60(K) Rc 1 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 600 800 400 200 Flow rate (l/min (ANR)) 0 2000 00 5000 10 0 0 1000 3000 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure Characteristics
flow rate (L/min [ANR]) Standard dew point Nil None (Standard) (oC) 30 50 60 75 100 P R With fitting for purge air discharge Nil 20 300 500 Select from Series IDG Flow direction (Right m Left) H L S 15 300 500 Note) In the case of two or more options, 170 240 300 40 75 110 indicate them alphabetically. 50 100 150 60 Accessory Thread type Symbol Type Symbol Type Nil None (Standard) Nil Rc
How to Order Manifold Common exhaust Individual exhaust (VF1000 only) VV5F 1 1 04 30 VV5F1 3 04 31 Series Thread type Stations Thread type 1 3 5 VF1000 VF3000 VF5000 Stations 02 Nil Rc 02 Nil 2 stations Rc 00F 00N 00T G 2 stations 00F 00N 00T G xx Manifold model NPT xx 20 20 stations NPT 20 NPTF P, R port size VF1000 VF3000 VF5000 Symbol 20 stations NPTF > 1/8 1/4 3/8 1/2 Up to 10 stations
Model Wires[mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) When using the 600V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) Selection example of wire size when using HIV wires is indicated below.
(FR-RC-(H)()() [mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) 600V (HIV ) HIV(FR-RC-(H) ()()(1)(a)IV 11.2 2(HIV) 2] (12) [mm L1L2L3 L11L21 UVW PC B1B2 BUBVBW OHS1OHS2 LECSS-S5 LECSS-S7 2(AWG14) 1.25(AWG16) 1.25(AWG16) 2(AWG14) 1.25(AWG16) LECSS-S8 1. (1)(c) 2. 11 21 11 (c) (1)(a)(b) (2) a FVD5.5
Use wires 8) of the following sizes with the power regeneration converter (FR-RC-(H) :Mitsubishi Electric Corporation). Model Wires[mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) 13 15 13.
A B B 03 3 stations P port 1/8 Nil F N T Rc G NPT NPTF : : 12 12 stations Applicable blanking plate assembly SYJ5000-21-3A R port 1/8 Type 43P (5 Port/Base mounted) How to Order SS5YJ543P 05 C4 Applicable connector assembly Refer to page 35.