(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
.: AMX-OMX0018-B PRODUCT NAME Line filter MODEL / Series / Product Number AFF20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AFF30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AFF40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0019-C PRODUCT NAME Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0020-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
AMX-OMY0038-A PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK20-(F, N)01 ~ (F, N)02(B)(-2, 6, C, R, Z)-D AMK30-(F, N)02 ~ (F, N)03(B)(-2, 6, R, Z)-D AMK40-(F, N)02 ~ (F, N)04(B)(-2, 6, R, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5. Construction / Options / Replacement parts 10 6.
VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.
, NPT, G) Width across flats KA J DL DL RF MO DL MM HR E D E HN Air-hydro CA2H Air-hydro CA2WH Auto switch Made to order Precautions H1 AL Width across flats B1 Width across flats of hexagon hole WB 2-cushion valve A N F K N B C M H S + Stroke ZZ + Stroke With rod boot e 9 l f h + l ZZ + l + Stroke (mm) HN Stroke range Bore size (mm) B C (MAX) P A AL B1 D DL E F G H H1 HR J K KA M MM MO N
F Front flange type S 1pc. F G Rear flange type n "n" pcs. Steel tubing is not available with auto switches.
Temp.140'F (60"C)) Rod Boot (Rubber) (l\rax. Temp. 230"F (1 10'C) ) Stroke Min. = 1" (25mm) Max. :12"(300mm) Others Consult Factory 'When ordering stroke should be in mm not inches. Boi (ln. Nom.) 50mm (2) 63mm (2'/.1 80mm (3) 100mm (4) CyllndrType -J N R H J K Mounting B Bodystuds L Foot F Front Flange G RearFlange C Sgl. Clevis D Dbl.
M12 x 1.0 12.5 9.5 47 6 9 75 4 Series CJ5-S Dimensions R V Front flange type (F)/CJ5FS CA Rod cover side GB Piping port 2-M5 x 0.8 Piping port M5 x 0.8 GA NN MM Cover surface BA CB D FY FB 2-FC With head cover port in axial position (R) Mounting hole NB A BB FX FZ NA F FT S + Stroke Z + Stroke H (mm) A BA BB CA CB D F FB FC FT FX FY FZ GA GB H MM NN NA NB S Z Bore size (mm) 10 15 15 12
Deflection on A when load is applied on F. Table deflection when yawing moment is applied. Deflection on A when load is applied on F. Table deflection when roll moment is applied. Deflection on A when load is applied on F.
N T, F, N are order made specifications.
To 140" F High Temperature 20" F fo 212 F Low Temperature -2o' F To 140" F Single Actinq Double Actinq Single Actino Double Actino Single Actino Double Actino Supplv Pressure 20 to 100 psi Sional Pressure. 3 to 15 psi (split ranqinq possible) Rotarv Anqle (stroke) '10'to 28" (10-85mm) (0.3" to 3.4" std.)5.9max.l Linearitv* Within 1 1% Within + 2% Hvsteresis Within 1% Repeatability* Within
O f o r o l o C e s a e l e r n o t t u b f o r o l o C e s a e l e r n o t t u b g u l P t e k c o S g u l P t e k c o S e b u T . D .
SYJA3 20-M3-F The mounting bracket for the 2 position double solenoid and 3 position is supplied unattached.
N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
Panel mount adapter + Front protective cover ZS-27-D With M3 x 8 l (2 pcs.) 956 Voltage Monitor for PFMV5 Series PFMV3 Specifications Model Series PFMV3 Applicable sensor Series PFMV505(F), PFMV510(F), PFMV530(F) Displayable range 0.70 to 5.10 V: The voltage under 0.7 V is displayed as LLL and that of 5.1 V or more is displayed as HHH.
Gravity is applied. mg F l l mg Friction force is applied. Rotation shaft is vertical (up and down). 2 Ta = = t2 Ts = F l Gravity is applied in rotating direction.