High Precision, Digital Pressure Switch for General Fluids Dimensions Bracket A A 30 20 ZSE ISE 20 PSE 45 Z I SE3 55 4.5 11.5 40 15 PS 4.5 Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6.5 1.6 ZSP 20 41.5 ZS-24-A Bracket A View A ISA2 IS Bracket D ZSM
(Also, when switching bowl materials from a metal bowl with a level gauge to a polycarbonate or nylon product, the oil feed tube assembly must be replaced.) Please consult SMC separately. It is not possible to switch from a polycarbonate, nylon or metal bowl, or from a metal bowl with a level gauge to a 1000 cm3 tank.
(Also, when switching bowl materials from a metal bowl with a level gauge to a polycarbonate or nylon product, the oil feed tube assembly must be replaced.) Please consult SMC separately. It is not possible to switch from a polycarbonate, nylon or metal bowl, or from a metal bowl with a level gauge to a 1000 cm3 tank.
0.05 0.05 MK(2) Standard Stroke RS Q G Bore size (mm) Standard stroke (mm) RS H A 10, 16 5, 10, 15, 20, 25, 30 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50 RZQ Precautions MI W S CEP1 Be sure to read before handling.
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
Note 4) While inserting a tubing into an elbow fitting, hold the main body of the assembly by hand. Failure to do so will exert an undue force on the valve or the fitting, resulting in air leakage or damage. Indicator light a side: Orange b side: Green Solenoid a Solenoid b Back page 4 Series VV100 Specific Product Precautions 3 Be sure to read this before handling.
A fitting with an O-ring is used for a high vacuum rodless cylinder. Use a fitting that conforms to the dimensions below, and install it so that there is no air leakage. P (Port size) Operation P (Port size) Model CYV15 CYV32 Caution 5/16-24 UNF 7/16-20 UNF 1.
Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.
9 12 12 15 15 20 20 20 23 25 27 M5 x 0.8 M6 x 1 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 5.4 5.4 6.7 6.7 8.6 8.6 9.5 9.5 11 11 14 14 30.5 36.5 40.5 46.5 54.5 68.5 NPT1/8 NPT1/8 NPT1/8 NPT1/8 NPT1/4 NPT1/4 G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 14 16 20 20 26 30 MGPWL, MGPWA 20, 25/A, E Dimensions (mm) MGPWL, MGPWA 32 to 63/A, E Dimensions (mm) Bore
Note3) A reference value for correcting an error in reciprocal operation Note4) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to thelead screw. (The test was performed with the actuator in the initial state.)
GENEBAL Thi6 Speed Control is an Aluminum die cast Intsrface Plate having on its upper surface a mounting pattern wtlich accepts all SMC Class l solenoid and air oprated valves and with a lower surface which mounts onto all subplales and manitolds applicable to these Class 1 valves.
A maximum of 20 types of work can be classified by switching these banks.
When disassembling a cylinder with a bore of 20 to 40, use a vise or the like to hold the wrench flats portion of the tube cover or the rod cover on one side, while placing a wrench or an adjustable wrench on the other side to loosen and remove the cover. To replace, tighten it an additional 28 from the installed position.
C a u t i o n Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.
Note 2) Drain piping, or piping for a stop valve, like a ball valve, is required. 850 size comes with a ball valve. substitute with (Symbol: A).
Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.
Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate wiring specifications on a manifold specification sheet. (Note that double, 3 position and 4 position valves cannot be used where single solenoid wiring has been specified.)
Dual Rod Cylinder 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 RoHS Cylinder suitable for pushing , lifting , or clamping 48% Reduced by up to Overall length 59.5 mm 114 mm JMGPM25 20 mm stroke (20 x 2)1 CXSM20 20 mm stroke (20 x 2)1 JMGP25 CXSM20 59.5 mm 38% Reduced by up to 54.5 mm shorter (Compared at a 20 mm stroke) Weight 0.8 kg 1.28 kg CXSM32 25 mm stroke (32 x 2)1 JMGPM40 25 mm stroke (
Hs Auto switch 24.5 A B 49.5 A 33 B Proper auto switch mounting positions (mm) D-G39 D-K39 D-A3 D-A44 D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C D-B5 D-B64 D-G5NTL D-H7F D-B59W Bore size (mm) A B A A A A A A B B B B B B 16 15.5 7.5 12 14 17.5 12.5 11 19 20 8 4 6 9.5 4.5 25 17.5 13.5 17 7 15.5 19 10.5 14 20.5 7.5 3.5 5.5 9 4 32 20.5 16.5 9 20 18.5 22 23.5 12.5 17 9.5 5.5 7.5 11 6 40
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. -2No.SFOD-OML0002-A Caution 1.