: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Stations: 03 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size:
: Right to Left), Drain Cock w/Barb Fitting: W (Drain Cock w/Barb Fitting), Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
: Right to Left), Drain Cock w/Barb Fitting: W (Drain Cock w/Barb Fitting), Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03 (3/8)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03 (3/8)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03 (3/8), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03 (3/8)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03 (3/8)
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.