M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1
Maintenance 10 2. Application 11 3. Specifications 11 4. How to Order 12 5. Component name and spare parts list 13 6. Troubleshooting 14 7. Assembly and replacement procedure 7-1. Bracket assembly 15 7-2. Auto drain replacement 15 7-3. Element replacement 19 8. Dimensions 20 -2- Doc. no.
Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR
How to Order Bore size 10 16 10mm 16mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.
However, for any other mounting method or for side facing and rear facing, etc., secure the DIN rail with bolts at uniform intervals using the following as a guide: 2 to 5 stations at 2 locations, 6 to 10 stations at 3 locations, 11 to 15 stations at 4 locations, and 16 to 20 stations at 5 locations.
RH (No condensation) Standards and regulations CE/UKCA marking (EMC directive, RoHS directive) Material of fluid contact parts PPS, FKM, Brass Port size 3/8(10 A) 1/2(15 A) 3/4(20 A) 1(25 A) Weight(Body) *9 Approx.
12 14 B 11 27 13 12 9 2A 2 2B 2 12 18 2 7 - 3-4 2B2C A 16 17 12 18 2 8 9 13 B 11 9 10 17 A 16 12 18 2 2 O 3 19 12 27 12 14 27 15 12 12 3-5 2C2B OPENCLOSE 9 B 11 10 A 16 18 2 2 12B 11 9 27 13 12 14 27 15 9 B 11 12 13 2 19 3-6 2B 2A 2 18 12 9 2 21 23 3-7 20 22 24 8 8 - 4. 4-1.
robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.
No.EX-OML0011-C PRODUCT NAME Fieldbus Device Handheld Terminal MODEL / Series / Product Number EX600-HT1A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Names and Functions of Product 8 Definition and terminology 9 Mounting and Installation 10 Precautions before mounting 10 Wiring 11 Setting and Adjustment 12 Basic operation 12 Mode selection 13 1.
Do not modify the internal electrical wiring of the product. 10.2 Earth leakage breaker specification Models Item IDFC60-23-R IDFC70-23-R IDFC80-23-R IDFC90-23-R Rated current (A) 10 15 20 30 Sensitivity current (mA) 30 IDFC60/70/80/90 Series 10.1 Safety instructions for use 10-1 IDX-OM-U010 Chapter 10 Option R 10.3 Connection of power supply Connect the power cable according to the procedure
Option [Actuator cable] LE CP 1 B S Cable type Cable length Nil S Robotic cable Standard cable 1.5 m 3 m 5 m 8 m 10 m 15 m 20 m 1 3 5 8 A B C Motor option Nil B Without lock With lock Produced upon receipt of order (Robotic cable only) [I/O cable] Pin no.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. *2) Labor Safety and Sanitation Law, etc.
B B B p AW3001 220.5 213.5 219.5 240.5 AW4001 272 265 271 292 IN-OUT reversal mounting "'" DimenSions except B are same as the standard type.
Do not modify the internal electrical wiring of the product. 10.2 Earth leakage breaker specification Models Item IDFB60-11-R IDFB60-23-R IDFB70-23-R IDFB80-23-R IDFB90-23-R Rated current (A) 15 10 15 20 30 Sensitivity current (mA) 30 IDFB60/70/80/90 Series 10.1 Safety instructions for use 10-1 IDX-OM-V024 Chapter 10 Option R 10.3 Connection of power supply Connect the power cable according
Electric circuit 10 5. Relation between Pressure setting and operating pressure 10 6. How to Order 11-14 7. Structural Drawing 15 8. Type of scale 15 9. Pressure Setting Method 16 10. Trouble Shooting 17-18 11. Dimensions 19-21 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
g k ( s b l t h g i e W ) 7 . 0 ( 4 5 . 1 ) 1 . 1 ( 3 4 . 2 ) 5 . 2 ( 1 5 . 5 ) 5 . 4 ( 2 9 . 9 t e k c a r B P 4 2 B P 5 2 B e g u a G 5 2 O R A N . d t S ) g i s p 0 6 1 ~ 0 ( n o i t p O K50A-MP1.0-N02M K50A-MP2.0-N02M 5 3 O R A N . d t S ) g i s p 0 3 ~ 0 ( How To Order N R NAR 4 25 02 B Body size Option 4 1/2 6 1 8 11/2 9 2 Nil None R IN-OUT Reversal (RightLeft) Pressure regulating
Spanner Nominal: 10 Tightening torque: 2.6 Nm AW60(K) 5. Square Embedded Pressure Gauge Process Procedure Tools Check item Applicable model Disassembly 1) Remove the pressure gauge cover. Rotate the pressure gauge cover 15 degree counterclockwise to pull out the pressure gauge cover. AW20(K) AW30(K) AW40(K) AW60(K) 2) Remove the pressure gauge.