Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.
Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2
ASR/Series ASQ How to Order Pressure valve: Series ASR ASR F20 4 3 0 F S 02 06 With seal Model ASR Pressure valve Option ASQ Flow valve Variable set pressure type (0.1 to 0.3 MPa) Nil Body size 4 5 6 1/4 standard Fixed set pressure type (0.2 MPa) F20 3/8 standard Regulator with check valve and flow control valve integrated into a single construction 1/2 standard Applicable tubing O.D. 06 08
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
/I.D. mm 8/5 9/6 10/6.5 12/8 12.5/8.5 16/11 Symbol 01 02 03 04 06 Symbol 50 60 65 80 85 110 Symbol 04 06 08 10 12 16 Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Tubing O.D. mm 4 6 8 10 12 16 Construction
Load factor: ( (Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 1 LPM , 1 LPM, Max Pressure: 12 PSIG / 827 mbar , 12 PSIG / 827 mbar, Max Vacuum: 19.4 in HgV / -658 mbar , 19.4 in HgV / -658 mbar, Voltage (DC): 12, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Stations: 08, A,B Port: N7 (ø1/4" One-touch Fitting, Inch), Thread: T (NPTF)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Handle Position: B (Front), Piping: 3 (IN: Bottom/OUT: Top), Stations: 3 Stations, Fitting: 08 (IN: Straight Ø6, OUT: Straight Ø6), Accessory: A (Pressure Gauge), Option: None, Unit: Z [Name Plate, Gauge & Pressure Switch w/Unit Switching Function (PSI)]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Stations: 08 (8 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Laterial vacuum entry without buffer series, Pad diameter: 02, 04, 06, 08, 10, 13, 16, 20, 25, 32, 40, 50 (mm), Pad style: flat, flat w/ribs, deep, bellows, Material: NBR, silicon rubber, urethane rubber, flourine rubber, EPR, Rotating or non-rotating, Multiple vacuum entry/mounting thread diameters VACUUM PAD, ZP, ZP2, ZP3. VACUUM PAD WITH BUFFER. 24.70000 lb. M30.