Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
Q1 5 4 () 1) () Q2 1)+COM (4) 7) (2)1U (3)J1,J2, Q2 (11) (P ) L L 0.3m 0 (M5x0.8) LO L 2 4 3 6 (5) 5 4 2) B (12) (2):1U 2)(3)Q1 8) (3)Q2 Assy N C 3) ) (6) ( D [kPa] (2):3M EA NPN2 9) 8) (PD) EB PNP2 0 to -100 EC NPN1 + S EE PNP1 + C FA NPN2 D FB PNP2 -100 to 100 8)VQ100 Ass yP.41 FC NPN1 + FE PNP1 + (3)Q2 (4)LO 9)(3)J1,J2Q2 P.6 (3)C 4) F 3) ZFC 4
L4 Note) Weight (g) 3 5 5.5 6.5 8.5 9.5 19 22 36 38 42 44 76 82 Model D1 Applicable tubing O.D. d AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 3.2 5 6 25.4 36 37 39.5 40.7 42.5 53.2
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Auto Switches/Direct Mount Type D-F8N, D-F8P, D-F8B Auto Switch Specifications Grommet D-F8 (with indicator light) D-F8N D-F8P D-F8B Auto switch part no.
Flow Rate and Sonic Conductance Model AS1002FS AS2002FSAS2052FS AS3002FS AS4002FS Metric size 3.2 4 6 4 6 6 8 6 8 10 12 10 12 Tubing O.D.
Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)
EX600-ZT1 (6)Assembled type connector PCA-1446553: For EtherNet/IPTM communication, M12 (4 pin) Plug, D code PCA-1578078: For power supply, 7/8 inch, Plug, Cable O.D. 12 to 14 mm PCA-1578081: For power supply, 7/8 inch, Socket, Cable O.D. 12 to 14 mm (7)Power supply cable PCA-1558810: Cable with 7/8 inch connector, Socket, Straight 2 m PCA-1558823: Cable with 7/8 inch connector, Socket, Straight
235.5 225 248 260.5 250 234 285.5 275 255 248 273 L1 L2 L3 L4 237.5 213 17.5 237.5 262.5 223.5 244.5 202.5 16.5 13 15 12 14 37 5 Port Solenoid Valve Series SX3000/5000 Stations SS5X3-45GDC4 C6 Note) L1 to L4 dimensions of SS5X3-45GUStations Uare the same as SS5X3-45GUStations D-.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.
ASN Flow Rate and Sonic Conductance AQ ASV AS1001F AS2001F AS3001F AS2051F AS4001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D.
NPN (2 outputs) -B PNP (2 outputs) Brown DC (+) Brown DC (+) Load Black OUT1 Black OUT1 Load Load Load Load Main circuit Main circuit Main circuit + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load FUNC FUNC Blue DC () Blue DC () -C NPN (1 output) + Analog voltage output -D NPN (1 output) + Analog current output Brown DC (+) Brown DC (+) Load Load Load Black OUT1 Black OUT1 + + White
8618 -31208 -10 -5 -20 F 8000 -32767 -10.5 -5.25 -21 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB -23No.EX-OMN0037CN-A -24No.EX-OMN0037CN-A EX600-AY A M12 (5 )2 2 M12 (4 ) No. 1 LED 2 () 3 4 5 () -25No.EX-OMN0037CN-A 1 24 V() 2 3 0 V() 4 0 V() 5 FE M12 (4 ) 1 24 V 2 D/A DC24 V 34 0
M D2 L A D1 NPT, R(PT) Nylon Urethane M5 0.8 M6 1.0 KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S 36.5 9 12 37 33 8 16 10.4 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 1 8 M5 0.8 M6 1.0 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 12 2.5 3 4.0 4.0 5.6 5.6 12 8 6
(mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.
Auto Switch Proper Mounting Position (mm) (mm) Auto Switch Mounting Height D-M9 D-M9W D-M9 D-M9W D-A9 Auto switch model Auto switch model D-A9 B A B A Bore size Bore size 20 25 32 40 Hs 30.5 59.5 34 55.5 20 25 32 40 Note) The above values are a guide in the stroke end detection of the mounting positions of the auto switch.
(Sinking type) 12 to 24[V DC] NPN transistor MAX80[mA] MAX30[V] Main circuit Load Detection Switch Fig.1 Connection example of NPN output PLC High level 12 to 24[V DC] MAX80[mA] MAX30[V] Main circuit Load No current flow. Load is not powered. Fig.2 Equivalent circuit of an NPN switch with the output off PLC Low level 12 to 24[V DC] MAX80[mA] MAX30[V] Main circuit Load Current flows.
Configuration One thermo-chiller for one controller. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.