Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m
Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m
Rated Pressure Range: -100 to 100 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C4H (One-touch Fitting ø4mm, Straight Type), Option 1: L (Lead Wire w/Connector, 2m)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, ISE20, "PRESSURE SWITCH, N lb
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, AIR PILOT, VALVE, VSA AIR OPERATED VALVE, H7, VSA BODY PT 3/8, 0.64564 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, VG/VGA VALVE, LB, VG BODY PT >3/4, 2.44075 lb
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
This is a legacy product. Please contact us for the latest version.sales@ocaire.com NEW SY50008/7000 MANIFOLD. MANIFOLD. VALVE. NEW SY5000 MFLD, OTHER SIZE. 1.70329 lb. 1P.
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE, MEDIA (N.C), 2 PORT VALVE, K84, 1.28 lb
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., Valve, Media (N.C.), 2 PORT VALVE, K84, 1250.00000 lb