Ambient and fluid temperature (C) 0 to 60 Lubrication (1) Required (Use turbine oil Class 1 ISO VG32.) Mounting orientation Free Impact/Vibration resistance (m/s2) (2) 150/50 Note 1) Use turbine oil Class 1 (ISO VG32).
One-touch fitting for N9 One-touch fitting for One-touch fitting for One-touch fitting for 5 16" CE-compliant SY7000 3 8" N11 N9 N11 Electrical entry Nil 5 16" SY9000 Grommet L plug connector 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/ 100, 110, 200, 220 VAC M plug connector DIN terminal Q CE-compliant 3 8" For DC only except DIN terminal.
Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. q w Locking nut t Wiring Warning e 1. Since the light emitting diode (LED) is used for the light assembly for 24 VDC, there are 2 terminals and polarity. One is + for red load wire and the other is for black load wire. Light will not light up if wired incorrectly. 2.
A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19
Install the valve guide (on the opposite side of the handle) 60 mm away from the ground surface to facilitate maintenance inspection. 2. Do not use the regulator with flow exceeding the Max. flow indicated in Flow Characteristics as this can cause failure in pressure adjustment.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSE3 Vacuum Q CE marked products Note) Only available with output specifications 21 and 23.
Indicator light and surge voltage suppressor Coil voltage None With surge voltage suppressor With indicator light and surge voltage suppressor S Z 100V AC(50/60 Hz) 200V AC 110V AC 24V DC 12V DC Others voltages 1 2 3 5 6 Note) Coil voltage 100V AC: With surge voltage suppressor. Note) "YOZ" is not available. 9(1) Note 1) Contact SMC for other voltages.
Case Replacement Parts q Gasket for cover case AL-204H AL-205H ZFA100 Part no. ZFA200 No. Description Selection Warning 1.
cylinders Bore Stsoke O25-1/ainch a37-/eirch Ofi_r/zinch O75 3/ainch Stroke o6 (1h,) O'tO (Es"\ q15 (SB'I % , % , % , % % , % , ' / r , % , ( Y , 1 % 1OO-1 inch 125-11/4inch '{r inch soacer is added to the 1 % inch strcke cylinder o Series NCJP a :Available X : Not available Standard Accessories 8.8 PSI (0.6k97cm.) 20 PSI (1.2kgflcmr) 100 PSI (7kgf/cm,) 150 PSI (9.gkglicm,) 40 140"F (5 -60
Be sure to loosen the locknut before adjusting the knob by hand. r After adjustment, tighten lock screw for tamper proof operation, Fluid-Air/Supply 1 05psig (7 kgt / cm2l NSR 1110 to-32^lrn {l',151 NSR 3110 NSR 4110 %tlPf 75 75 g q 6 0 il IJ I 6 a 60 d 5 F "ff 45 * 3 0 d 30 1 5 0 o o 7 1 4 2 1 2 A 3 FWSSM P r e ssur e C -lwr a ct eri st i e s Supply pressure 1OOpsig (7kgt/cm2l, Secondary
Information that can be copied includes the following: q Pressure set values, w Range settings, e Display Units, r Output modes, t Response times. 5% R.D. Displayed pressure value When CH1 is copied to CH2, CH3, and CH4, information of OUT1 in CH1 will be copied. When CH2, CH3, or CH4 is copied to CH1, information of OUT1 in CH2, CH3, or CH4 will be copied only to OUT1 in CH1.
MG Minimum Operating Pressure (MPa) Symbol Specifications Min. operating pressure (MPa) 6 0.12 10 0.06 16 CX Bore size (mm) -XB13 Low speed cylinder (5 to 50 mm/s) 0.06 DTheoretical Output (N) -X Operating pressure (MPa) Operating direction Bore size (mm) 0.7 0.5 0.3 2015 11 6 IN 6 20 14 8 OUT Data 46 33 20 IN 10 55 39 24 OUT 121 86 52 IN 16 141 101 60 OUT Standard Stroke Bore size (mm) 6
: 0.55 MPa, Fluid: Air 0.5 r Outlet pressure MPa 0.4 0.3 OUT IN 0.2 33 0.1 2 x Rc 3/4 to 1 0.0 t e y q 0 1000 2000 3000 4000 Flow rate L/min (ANR) Component parts Material No.
Guide) Flow Rate/Operating Frequency (Supply pressure 0.25 MPa, 24 VDC, Duty ratio 1:1) Flow rate 150 High flow 2 High frequency type Medium flow 100 3 1 Super energy-saving type Ultra high frequency type Low flow 50 150 250 350 400 500 550 650 1200 (Hz) (L/min) Operating frequency Specifications Driver Continuous energization Power consumption OFF response time 50 L/min 100 L/min 150 L/min q
The oil that has been pumped from the tank passes through felt q where it is filtered, and is fed into the case through nozzle w. When the volume of oil reaches a certain level, float e ascends, valve t descends via lever r, nozzle w closes, and the feeding of oil stops, thus completing the oil feeding process.
R 3 VDC 8 One-touch fitting C8 10 One-touch fitting 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 2(B) (A)4 Rated voltage 10-SY7000 C10 C8 C10 C12 3 For AC ( Hz) 50 60 Thread type (EA)5 1 (P) 3(EB) 1 100 VAC 2 200 VAC 10-SY9000 Rc Nil 3 position exhaust center F G 2(B) (A)4 3 110 VAC [115 VAC] N NPT One-touch fitting (Inch size) 4 4 220 VAC [230 VAC] NPTF T Symbol Port size
(For type 20 manifold) M 1 SYJ3 2 5 M M3 10 Body ported M 1 SYJ3 4 5 M 10 Base mounted CE-compliant Clean series Port size Nil Q CE-compliant 3 port Nil: Without sub-plate M5: M5 port With sub-plate Note) CE-compliant: For DC only.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Plug-in manifold with power supply terminal 10-SS5Z3-60 F U P D 1 05 Clean series CE-compliant CE-compliant Nil Q Connector type Option F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) SUP/EXH block mounting position When a longer DIN rail is desired than the specified stations, specify the station number to be required
Rated voltage Manual override Symbol Nil: Non-locking push type A: Non-locking push type (Manual) E: Push-turn locking type (Manual) DC AC (50/60 Hz) 2(A) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] 5 24 VDC 6 12 VDC (P)1 3(R) Electrical entry Light/surge voltage suppressor DC AC Nil Without light/surge voltage suppressor S With surge voltage suppressor *1 DIN terminal