SMC Corporation of America
Elite Part Number Search
Search Results "LVM20R3-5A-10-Q"

Note 10) The anchor bolt xing brackets (including 4 M10 bolts) are used for xing to wooden skids when packaging the thermo-chiller. No anchor bolt is included. 138 A

[10] Be sure to read this before handling the products.

When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released into the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e lifts the diaphragm.

2 q Magnet 9 Piston 10 POM Seal piston 11 NBR 1/8 15 23 Scale plate 12 PC Wiring Warning Mounting Warning Pressure Source Warning 1. 1. 1. Connect load before connecting with power source. The switch will break instantly if no load is connected. Make the wiring length as short as possible.

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.088 lb

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.08 lb

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

(See q.) If current decreases at this point, the flow rate may not change by 135 mA due to hysteresis. (See w.) The flow rate at increasing current and decreasing current are not the same due to hysteresis. (q 85 l/min., e 93 l/min.) Condition 2. P1 = 0.7 MPa, P2 = 0.2 MPa Refer to curve B when P is 0.5 MPa.

Note 10) The anchor bolt xing brackets (including 6 M8 bolts) are used for xing to wooden skids when packaging the thermo-chiller. No anchor bolt is included. 166 B

RoHS How to Order [Option] Q R06 L PS 00 10 Option (CE-compliant ) Nil Q None CE-compliant Output specifications 10 11 12 For positive pressure For vacuum and residual pressure For vacuum The PS1200 series is CEcompliant (with Q) only.

q Check the actuator label for model number. This matches the controller. w Check Parallel I/O conguration matches (NPN or PNP). q w Refer to the operation manual for using the products.

; price is per piece) $0.79 + Add to Quote Add To Cart Add to Cart SMC SX3000-52-1A-Q end block assy r, SS5Y3 MANIFOLD SY3000*** $10.00 Add

Q=240S P(P1+0.100) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q: Air flow ratedm 3 /min(ANR) Q=120S (P1+0.100) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

5 5 10 + 10 (n 2) (n = 4, 6) D-F7l D-J79 5 5 15 + 15 (n 2) (n = 4, 6) D-A9lV*2 5 10 10 + 15 (n 2) (n = 4, 6) D-A7l D-A80 D-A73C D-A80C Rail mounting 5 10 15 + 10 (n 2) (n = 4, 6) 5 10 15 + 10 (n 2) (n = 4, 6) D-A7lH D-A80H 5 10 15 + 15 (n 2) (n = 4, 6) D-F7lWV D-F7BAV D-A79W 10 15 10 + 15 (n 2) (n = 4, 6) D-A7lH D-A80H 5 10 15 + 15 (n 2) (n = 4, 6) D-M9l D-A9l*2 10

Auto switch model Bore size (mm) Operating Range 100 20 25 32 40 50 63 80 D-C7/C80 D-C73C/C80C D-B5/B64 11 10 10 9 10 8 11 17 10 14 10 14 9 14 10 13 8 13 11 16 11 18 D-B59W D-M9, M9W D-M9A 6.5 6 5 4.5 4 4 Since this is a guideline including hysteresis, not meant to be guaranteed.

CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 +0.036 0 8 8 +0.4 +0.1 41 +0.4 +0.1 48 +0.5 +0.1 48 +0.5 +0.1 56 (29.3) (33.1) (40.4) (49.2) +0.036 0 +0.036 0 +0.043 0 +0.043 0 31 37 38.5 42.5 5.5 5.5 6.6 6.6 10 10 10 10 42 48 53 60 20 25 32 40 25 30 35 40 5.5 5.5 6.6 6.6 10 10 10 10 36 43 50 58 20 25 32 40 +0.036 0 10 10 +0.043 0 12 12 +0.043 0 14

CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 +0.036 0 8 8 +0.4 +0.1 41 +0.4 +0.1 48 +0.5 +0.1 48 +0.5 +0.1 56 (29.3) (33.1) (40.4) (49.2) +0.036 0 +0.036 0 +0.043 0 +0.043 0 31 37 38.5 42.5 5.5 5.5 6.6 6.6 10 10 10 10 42 48 53 60 20 25 32 40 25 30 35 40 5.5 5.5 6.6 6.6 10 10 10 10 36 43 50 58 20 25 32 40 +0.036 0 10 10 +0.043 0 12 12 +0.043 0 14

LEP6 LEP10L LEP10 J K J K J K Low 7 14 12 24 12.5 25 Pushing force [N] Middle 8.5 17 16 32 19 37.5 High 10 20 20 40 25 50 Pushing speed [mm/s] 20 10 20 10 20 10 Pushing force accuracy is 30%F.S. for the LEP6 and 25%F.S. for the LEP10. Refer to the operation manual of the electric actuator for details.