Suitable screw torque (Nm) Body size M3 0.07 M5 0.3 1/8 1 1/4 1.5 3/8 4 1/2 10 15-8-6 Flow Control Equipment Precautions Series ASN2 Handling of One-touch Fittings Caution Selection 1. Refer to page 15-1-11 for One-touch Fitting. Warning 1.

If turbine oil is used, refer to the Material Safety Data Sheet (MSDS) of the oil. 1) M5 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/6 to 1/4 turn. As a reference value, tightening torque is 1 to 1.5 Nm. Note) If tightened excessively, the thread of the product may break or the gasket may deform.

1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300 Long 1,500 1,300 6 0.40 to 1.32 230 460 110 100 1 Short 1.00 to 3.05 18 36 160 140 1 1/4 Short 0.90 to 2.67 27 54 270 230 1 1/2 Short 1.10 to 3.29 45 90 270 230 2 Middle 0.68 to

AMX-OMZ0095 PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK50-(F,N)06 ~ (F,N)10(B)(-R,Z)-D AMK60-(F,N)10(B)(-R,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 6-1. Bowl assembly for AMK50 10 6-2.

ITVX Specifications PVQ VY1 SRH30 SRH40 SRH31 SRH41 Model Non-relief Relief Relief mechanism VBA VBAT Rc 1/8, 1/4 URJF 1/4 Rc 1/4, 3/8, 1/2 URJF 3/8 Rc 1/8, 1/4 Rc 1/4, 3/8, 1/2 Port size AP100 Grade A Clean air, N2, Ar, CO2, Pure water Clean air, N2 Fluid Grade B Air, N2, Ar, CO2, Water Air, N2 1.5 MPa Proof pressure 1 MPa Max. operating pressure Low pressure type High pressure type 0.02

4 3 1 7 9 SA 1 (P) VA 4 (B) 2 (A) 3 (R) 2 SA VA VH300/400 VM 8 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 VR 4 3 VH 1 9 VHS 7 4 (B) 3 (R) 1 (P) 2 (A) 2 VH600 6 5 4 1 7 1 (P) 2 (A) 4 (B) 2 3 (R) Component Parts Material VH200/300/400 Zinc die-casted Aluminium

431g 818g Note 1) Supply pressure: 1.0 MPa Port size Supply (INOUT) Exhaust (OUTEXH) Model IN, OUT EXH C(dm3/sbar) b Cv C(dm3/sbar) b Cv VHS20-D 1/8 1/8 4.0 0.41 1.1 3.7 0.42 1.1 1/4 5.8 0.31 1.4 3.8 0.42 1.1 6 VHS30-D 1/4 1/4 8.8 0.44 2.4 8.0 0.46 2.3 3/8 14.1 0.28 3.5 7.8 0.46 2.2 1/4 9.5 0.49 2.8 13.3 0.47 3.6 3/8 17.2 0.47 4.8 13.6 0.47 3.7 3/8 VHS40-D 1/2 26.7 0.29 6.3 13.4 0.43 3.7

Abnormal (19 V or less) Output area mapping For EX260-SEN1/-SEN2 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 For EX260-SEN3/-SEN4 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 -38No.EX-OMP0013-E Dimensions If a fieldwireable connector is used for the

Model Port size 4 6 8 10 12 ASD One-touch fittings for AS121-M5 AS221-01 AS221-02 AS321-02 AS321-03 AS421-04 M5 x 0.8 AS 1 8 R metal body specifications 1 4 R AS-FE 1 4 Uses flame resistant resin as standard. (UL standard V-0) R 3 8 R KE 1 2 R Note 1) : Brass parts are electroless nickel plated, provided as standard.

Designation Description 1 Tx+ Transmit Data + 2 TxTransmit Data 3 Rx+ Receive Data + 4 5 6 RxReceive Data 7 8 BUS IN: RJ45 8-pin socket No. Designation Description 1 Tx+ Transmit Data + 2 TxTransmit Data 3 Rx+ Receive Data + 4 5 6 RxReceive Data 7 8 Use only plugs conforming to FCC standards. Shielded Ethernet cable is recommended.

Applicable tubing size Series Symbol q w e r Position Nil P2 P3 P4 Tubing outside Applicable series LVP5 Orifice dia. Body size Symbol Symbol diameter 22 mm 26 mm 32 mm 5 6 16A 20A 25A 16 mm 22 mm 5 6 LVP6 Symbol Pilot port thread (fitting) type A Symbol Nil 1 2 N Thread (fitting) type 6 mm One-touch fitting Rc1/8 M5 x 0.8 NPT1/8 PA B N.C. A PB Option B Applicable valve type N.C. N.O.

8 1 8 .13 (57) NARM1000 (79 X n) + 25 Individual IN 1 8 1 8 Common IN (188 X n) + 43 1 4 1 8 .3 (136) NARM2000 Individual IN (187 X n) + 45 1 8 1 8 Space Saving How to Order Option NARM 1000 A1 5 01 G 1 1 Set at 0.2MPa Note1) Pressure gauge for 1MPa is used.

SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice. ii HEF002-A6 Contents Contents 1 PREPARATION FOR COMMUNICATION -1-1 2 OPTIONS OF COMMUNICATION METHOD -2-1 2.1

340 369 3/4, 1 615 3/8, 1/2 FGH300 70 x L496 591 620 3/4, 1 69 HEPO2Element for FGH Series EJ Series RoHS Specifications Model EJS-002 EJS-004 EJS-006 EJS-013 Filtration accuracy (Filtration efficiency 99%) 2 4 6 13 1890 2310 2090 2490 117 mm Length Filtration area (cm2) 4250 5200 4700 5600 246 mm 8500 10400 9400 11200 496 mm Heat resistant temperature (C) 80 Filter media Polyester Material

SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice. ii INR-244-831 Contents Contents 1 PREPARATION FOR COMMUNICATION -1-1 2 OPTIONS OF COMMUNICATION METHOD -2-1

1.4 0.26 0.12 1.2 1 8 VFS Double check VZS2650 500 26 or less 0.3 0.81 0.71 1 8 VS4 Note 1) Min. operating cycle is based on JIS B 8375 (One time per 30 days).

Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-41 Series VZM500 How to Order S 01 01 0 VZM55 Option Suffix for actuator F Foot bracket Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push button selector Rc 01 1 8 Roller lever 01 Black 1 8 NPT N01 One way roller lever 02 Green G F01 1 8 Straight plunger 05 Y Yellow Roller plunger

Description Material Note 1 Body PBT Caution 1. Quality of supply air 2 Diffuser PBT Type S: White, Type L: Black 3 Cap POM Use clean compressed air as fluid. (Air quality class 2 : 4 : 3, 2 : 5 : 3, or 2 : 6 : 3 as specified in ISO 8573-1: 2010 is recommended.)