SMC Corporation of America
Elite Part Number Search
Search Results "KQB2H11-13"

Assembly of a piston and a seal (KSYP-13). Note 2) Check valve assembly is applicable for a regulator with backflow function (AR20K to AR60K) only. Assembly of a check valve cover, check valve body assembly and 2 screws Options/Part No.

SeriesNCA1 Air Cylinder: Standard Type Double Acting, Single Rod Maintenance Parts 150 to 400 Construction 15 17 13 14 16 Seal Kit Parts List No. 13 14 15 16 17 Description Cushion Seal Rod Seal Piston Seal Cushion Valve Seal Cylinder Tube Gasket Material NBR NBR NBR NBR NBR Kit no.s can be found on the next two pages. *Call or email us at sales@smcpneumatics.com for request.

NCQ8B200-PS NCQ8B200-PS 200 (2") NCQ8B250-PS NCQ8B250-PS 250 (2 1/2") NCQ8B300-PS NCQ8B300-PS 300 (3") NCQ8B400-PS NCQ8B400-PS 400 (4") Construction Double Acting, Double Rod SeriesNCQ8W 15 13 14 Seal Kit Parts List No. 13 14 15 Description Piston Seal Rod Seal Tube Gasket Material NBR NBR NBR Repair Parts: Standard Seal Kit for Double Acting, Double Rod Remarks Bore size Kit no.

Nil (Example) M9N 1 m M (Example) M9NM 3 m L (Example) M9NL 5 m Z (Example) M9NZ Note) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper. 530 MHR3/MDHR3 Series Rotary Actuated Air Gripper 3-Finger Type Model/Specifications Nominal size 15 10 Action Double acting External grip 13

SFD-EL101 SFD SFD Element set Element set 1 1 With O-ring With O-ring Bracket Bracket 2 2 Material: Stainless steel 304 Material: Stainless steel 304 SFD-BR101 SFD-BR101 LLB Dimensions AD SFD101-02 SFD102-02 GD 25 66 66 25 19 19 24 24 50 40 50 40 13 2 x 4.5 Bracket Bracket 13 2 x 4.5 325 SFD Series Made to Order Specifications 2 Please contact SMC for detailed specifications, delivery and

17 13.5 10.5 10 10 23.5 4 12 20 M15 X 1.5 3.5 17 15 30.5 27 24 5 19 14.5 11.5 15 10 5 25 19 M22 X 1.5 20.5 4.5 17.5 15 31.5 27 24 Panel Mounting Style CJPB B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13

TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60

19.6 11.8 6 11.6 11 6 11.6 6.3 44.8 AQ240F-07-00 AQ240F-07-07 13.7 13.7 15.4 6.2 13.7 27.3 40.7 8 10.0 15.1 6.2 1/4" 12 6 1/4" 12 40.7 AQ340F-07-00 AQ340F-07-07 16.8 20.3 13.7 16.8 7.1 52.2 33.1 20.0 13 11.8 1/4" 13.2 11 1/4" 13.2 7.1 22.2 15-12-4

An air dryer or water separator should be installed upstream from the filters. 15-16-13 14 Air Saving Valve Specific Product Precautions Be sure to read before handling. Tightening Torque Selection Warning 1. The proper tightening torque for pipe fittings is as shown in the table. As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand.

D2 L A M D1 Nylon Urethane M5 X 0.8 M6 X 1.0 38.5 KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S 11 13 39 35 8 16 10.4 2.5 4.0 4.0 4 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 12 1 8 M5 X 0.8 M6 X 1.0 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 17 15 12.8 38 39 42 43 44 1 8 1 4 1 8 20 26 28 34 42 68

Provide intermediate supports for cylinders with long strokes to prevent rod damage due to sagging of the rod, deflection of the tube, vibration and external loads, etc. 13 Series MGZ Actuator Precautions 2 Be sure to read before handling. Mounting Lubrication Caution Caution 1. Be certain to align the rod shaft center with the load and direction of movement when connecting.

Bore size Bore size MLGClB RSMLGC , #1 (#1+#4) Bore size Bore size MLGClB SMLGC , #3 (#3+#4) 3.2-7 Series MLGC Front Flange Mounting/With Rear Plate MLGClFl-l-RStandard Stroke AN BP AG AM GK AB AL B GD A Bore size (mm) Stroke range (mm) AA AH AI AJ AK AO AP BZ GC 1/8 1/8 1/8 1/8 20 25 32 40 75, 100, 125, 150, 200 75 3.5 13 9 54 94 11 92 9 M8 32 28 134 150 108 140 135 Rc(PT) 73.5 88 4 16 9

Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B B A W A B stroke 6 5 to 30 3.5 0 17 6.5 13 3.5 2.5(5) 17 4.5 5 to 20 17 13 17 10 25 7.5 3.5 20 16 2.5 7.5 20 1.5 0.5 30 19 15 19 (1) 5 27 23 27 10 22 18 22 15 27 23 27 16 8 4 2 8 2 0 B A 20 22 18 22 Bore (mm) 6 10 16 25 27 23 27 (0.5) 6.9 10 30 27 23 27 8.8 14 13.9 19 Note 1) Negative figures

mounting (M4) VQZ Coil fitting position 4 positions per 90 Coil fitting position 4 positions per 90 VZ VS 2-M6 mounting hole For top mounting (M4) Manual override (Non-locking) VFN Manual override (Non-locking) DIN terminal facing upward (101.6) Max. 10 (Coil positioning pin) (Coil positioning pin) 2-M6 x 1 for bottom mounting 2-M6 x 1 for bottom mounting Applicable cable O.D. 6 to 12 4-7-13

DXT083-13-1 Qty. 1 pc. VZ Hexagon socket head screw DXT083-19-1 2 pcs.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VR VH VHS 3 (Breathing port) 3 (Breathing port) (Piping port) (Piping port) 3 4 5 3 position closed center/exhaust center/pressure center: VFA3 40-02 03-X1 (Mounting hole) (Pilot port) Breathing port (Piping port) 5-3-13 6 4/5 Port Air Operated Valve

DIMENSIONS 12~13 Pressure Relief 3 Port Valve With Locking Holes Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Push down the lever Slide the table in the direction of the arrow. 13 With buffer mechanism Caution Use air slide table with buffer in positions below. In horizontal operation, the buffer moves when operation starts depending on the load and the speed, starting the auto switch. Adjust the speed per load.

If a greater rotational torque is applied, the nonrotating rod (page 415) bends, exceeding the value of the non-rotating accuracy. 100 13 17 22 30 410 Guide Table Series MGF Operating Conditions Allowable eccentric load Allowable horizontal load The maximum value of load which can be applied at an eccentric position at a distance of l (mm) from the cylinder center. l l m m0 (Load center of

x P G Port size Port size DIN terminal A B C D J K Q T I Cable 6 to 12 S 12.5 R 1/4 Exhaust port (44) U F G1/2 E H L G 2 x P Port size Dimensions (mm) Model Port size P A B C D E F G H I J K L S VXF24A< 80 118 23.5 62.5 39 16.5 30 2 136 112 112 78 185 40 Grommet Grommet (with surge voltage suppressor) DIN terminal Model Q R U Q R U 27 20 175 30 20 161.5 VXF24A< R U T 64.5 20 167 52.5 Q 13