B-1 A-1 B-2 A-2 B-3 A-3 Connector C terminal no. Signal Cable color Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.
Note 6) : For thread type: NPT only 1075 A 1021-AR-B Regulator 1021-ARK-B Regulator with Backflow Function Standard Specifications 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Pressure gauge port size 1/8 Air Preparation Equipment Pressure Control
phase J B C D A t A COM COM COM B 12 VDC GND F.G.
): Dimension of the D-A96 D-A9V D-M9V D-M9WV D-M9AV Auto switch Auto switch Hs Hs A B A B 21.5 (23.5) 23.5 14.5 14.5 12.5 12.5 ( ): Dimension of the D-M9AV D-A7/A80 D-A73C/A80C D-A79W D-F7/J79 D-F7W/J79W D-F79F/F7BA Auto switch Auto switch Hs Hs Hs Hs A B A B D-A7H/A80H D-F7V/F7WV D-F7BAV D-J79C Auto switch Auto switch B A A B 10 Auto Switch Mounting Series CJ2Y Auto Switch Proper Mounting
CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
(B) 2 (A) 4 (B) 2 (A) 4 Operating pressure to 0.7 0.1 to 0.7 0.2 to 0.7 2 position single Pilot pressure range (MPa) 2 position single 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) 3 position Ambient and fluid temperature (oc) Max.60 3 position closed center 3 position closed center Lubrication Not required (B) 2 (A) 4 (B) 2 (A) 4 Mounting position Free 300/50 Impact/Vibration resistance (m/s2) (1) 1 (P
O 2 x N 4.2 b Section b-b Use two through-holes for mounting. 50, 63 Flat washer: 4 positions (Included) 4 x RR 4 x RH Washer b' 4 x O 4 x N b' Section b'-b' Use four through-holes for mounting.
C A B C A B C A B C A B C A B C LEY40 1100 Work load [kg] 1 1.5 3 2.5 5 10 4.5 9 18 7 14 28 1 1.5 3 1.2 2.5 5 Lead 4: LEY40C 800 900 1000 Pushing force 85% 65% 85% 65% 95% 95% Lead 8: LEY40B Lead 16: LEY40A 10 20 30 40 50 60 70 80 90 0 100 200 300 400 500 600 700 Force [N] Non-rotating Accuracy of Rod Size Non-rotating accuracy q 16 1.1 25 0.8 32 0.7 40 + Max. 65% Set value of pushing force
HA AT (G) (B) (D) ID (H) AMG Purge air for dehumidification AFF AM Misc.
A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.
B side traveling parallelism to A side Refer to Graph (1).
Material Description NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR Piston seal Rod seal A Rod seal B Brake piston seal Middle cover gasket Cam gasket Cushion seal A Cushion seal B Piston gasket Cushion ring gasket A Cushion ring gasket B Valve seal A Valve seal B Gasket for valve retainer Cylinder tube gasket $1 $2 $3 $4 $5 $6 $7 $8 $9 %0 %1 %2 %3 %4 %5 MGQ MGG MGC MGF MGZ CY
level gauge B B B B B B B Dimensions B Barb fitting Applicable tubing: T0604 Model Standard specifications Optional specifications Bracket mount P M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 A 25 40 53 70 75 90 95 B 77 115 142 176 176 250 268 C 26 36 38 40 38 41 45 D 12.5 20 26.5 35 35 45 47.5 E 30 38 38 45 G 35 60 80 110 110 110 110 J 12.5 20 26.5 35 35 45 47.5 M 30 41 50
D-A59W D-Z7/Z80 D-M9/M9W D-M9A Bore size (mm) Bore size (mm) D-Z7/Z80 D-A5/A6 A B A B A B A B A B A B Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs 40 50 63 80 100 40 50 63 80 100 11.5 8.5 8 5 13 10 5 2 27 28.5 27 34 35.5 28.5 29 27 13 8 9.5 4.5 14.5 9.5 6.5 1.5 33 33.5 33 38.5 39.5 34.5 33 33 4.5 0 8.5 3.5 47.5 38.5 14.5 9.5 11 6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54
A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13 80 16 14 12 10 9.5 7.5 11.5 9.5 9 7 6 4 6.5 4.5 12.5 10.5 8 6 10 8 17.5 15.5 100 17.5 16.5 13.5 12.5 11 10 13 12 10.5 9.5 7.5 6.5 8 7 14 13 9.5
P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. -31NO.ZK2-OM00501-B [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.
Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches.