Nylon, Soft nylon, Polyurethane 4, 6, 8, 10, 12, 16 Specifications Fluid Air/Water (1) Maximum operating pressure 1.0 MPa 100 kPa Operating vacuum pressure Proof pressure Ambient and fluid temperature 3.0 MPa 5 to 60C (Water: 0 to 40C) (No freezing) JIS B 0203 (Taper thread for piping) Mounting section Nut section With seal or none (2) JIS B 0211 Class 2 (Metric fine thread) Thread Seal (
IDG60M, IDG100M are fitted with AMH micro mist separator with pre-filter. 1.77 3.53 5.29 Flow Flow Flow 10 25 50 100 200 300 500 600 750 1000 110 170 240 300 100 150 75 50 Single Type 76F (60C) Dew point Single Type 40F (40C) Dew point Single Type 4F (20C) Dew point 3.53 5.29 8.02 11.3 14.12 2.72 5.44 8.29 0.44 1.09 2.19 4.41 8.83 13.24 22.07 25.6 31.78 42.02 Model Inlet Model Inlet Model
pipe purge air away from dryer 3.6 3.6 3.6 3.6 3.6 3.6 7.25 7.25 A B C Dimension inch 12000 hours service/Maintenance kit Built-in synoptic dryer control panel Non-corrosive shuttle valves Ability to remove dryer towers without disturbing the connecting pipe work Alternative purge plugs available 11 11 11 11 11 11 11 11 Optional dew points . 100F (70C) Standard pressure dew point . 40F (40C
Cable length is selectable from 3 and , Improvement in the maximum operating temperature from 40C to 50C (Actuator portion only) 50 50 Mounting Method is Selectable among 3 Types. DIN Rail Mount Direct Mount Easy to mount on a profile. Able to collectively install controllers. Easy to install on the control box, etc.
Ambient operating temperature 0 to 40C Connected controller power voltage 100VAC 200VAC External connection method Connector Insulation resistance 500VDC, 50M or more 2. Secure a distance of 50mm or more between the body and control panel interior or other equipment, as this may cause fire or malfunction. Mounting DIN rail mount 3.
FR soft nylon 6, 8, 10, 12 Specifications Operating fluid Air, Water Note1) 145psi {1.0MPa} 435psi {3.0MPa} 32 to 140F {0 to 60C} Water 41 to 104F {5 to 40C} JIS B 0203 (Taper pipe thread) Thread portion Nut With sealant (Standard) JIS B 0211 Class 2 (Metric fine thread) Max. operating pressure Proof pressure Ambient and fluid temperature Thread Sealant (Thread portion) Note1) Applicable
LED for power supply, LED for alarm 5 to 40C (41 to 104F) Dimensions (mm) 1in=25.4mm LC6C220AD Dedicated teaching box LC51T1 02 TEACH 42 97 POWER ALM PARA AL-RES JOG MON I/O TEST 38 130 STOP SMC LC5-1-T1 TEACHING BOX 96 35 RET ESC/ $MODE 50 21
12.2 4.5 KKH4S-60N 6/9 70.6 20.4 5.4 17 16.5 56.8 60.5 KKH4S-65N 6.5/10 1/4 19 25.4 68.1 24.1 5.9 KKH4S-80N 8/12 69.8 35.1 7.4 19 17.4 55.4 59.1 KKH4S-85N 8.5/12.5 72.4 36.6 7.8 Specifications Fluid Operating pressure range Proof pressure Ambient and fluid temperature Plating, Sealant Sleeve lock mechanism Air, Water (standard industrial water) 0 to 1MPa 1.5MPa Air: 5 to 60C Water: 5 to 40C
S Coupler Series KK Related equipment Specifications Large effective area Light weight Fluid Air, water (standard industrial water) Operating pressure range 0 to 1.0MPa Proof pressure 1.5MPa Air: 5 to 60C Water: 5 to 40C Ambient and fluid temperature With electroless nickel plated (For copper free application), With male thread seal Plating, seal Efficiency Plug socket connection method
Operating fluid Air 145;si {1.0MPa} Max. operating pressure 1.3KPa {10Torr} Max. operating vacuum pressure Proof pressure Ambient and fluid temperature 435psi {3.0MPa} 32 to 140F {0 to 40C} Uni thread JISB0209, class2 (Metric coarse screw thread) Gasket Thread Sealant (Thread portion) C3604BD parts with electroless nickel plating Copper-free application 104 to 107 1 Surface resistance 135
Air, Water Note 1) Fluid Maximum operating pressure 1 MPa 100 kPa Operating vacuum pressure 3 MPa 5 to 60C, Water: 0 to 40C (No freezing) Proof pressure Ambient and fluid temperature Brass parts are all electroless nickle plated. Copper-free (Standard) Note 1) Applicable for general industrial water.
Specifications Fluid Air, Water (standard industrial water) Operating pressure range 0 to 1.0MPa Proof pressure 1.5MPa Air: 5 to 60C Water: 5 to 40C Ambient and fluid temperature Plating, Seal Electroless nickel plated, With male thread seal Connection plug Series KK Plug Efficiency Plug socket connection method One-tough installation and removal Check valve Socket: Built-in check valve Sleeve
Min. bending radius (mm) Note) 4 Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) Material Polyurethane Color Black(B), White(W), Red(R), Blue(BU), Yellow(Y), Green(G), Clear(C) Burst Pressure Characteristic Curve and Operating Pressure Note) At a temperature of 20C bend the tubing into a U shape.
Further more, conduct replacement using an IN, OUT differential pressure of 0.1MPa as a guide. 2) Start replacement after confirming that the temperature of the filter body is within a range of 0 to 40C. 3) When setting the element, be sure that it does not tilt inside the case. Adjust initial pressure drops to 0.01MPa to 0.02MPa or less. 6.
Technical Data Related Products Applicable model Common for all models Circulating fluid recoverable volume Note 1) 3.2 gal (12 L) Nitrogen gas Purge gas Self-align fitting for O.D. 0.3in (8mm) Note 2) Purge gas supply port 58 to 102 psi (0.4 to 0.7 MPa) Purge gas supply pressure 0.01 or less Purge gas filtration 22 to 44 psi (0.15 to 0.3 MPa) Note 3) Regulator set pressure 50 to 104F (10 to 40C
0.02 35 or less1250/20Ball screw + Belt (Motor parallel)Sliding bearing (LEYGlM), Ball bushing bearing (LEYGlL)41 to 104F (5 to 40C)90 RH or less (No condenstation)l4236Servo motor (24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 (0.15) (Screw mounting), 0.37 (0.17) (DIN rail mounting)Non-magnetizing operation type17.5524 VDC ?10%
0.021050/20Ball screw + Belt (Motor parallel)Sliding bushing (Piston rod)41 to 104F (5 to 40C)90 or less (No condensation)l2830Step motor (Servo/24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%404 (Horizontal)/6 (Vertical)590.33 lbs ( 0.15 kg) (Screw mounting), 0.37 lbs (0.17 kg) (DIN rail mounting)Non-magnetizing operation type4.5 (20)3.624 VDC ?10%
0.021250/20Ball screw + Belt (Motor parallel)Sliding bushing (Piston rod)41 to 104F (5 to 40C)90 or less (No condensation)l4236Step motor (Servo/24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 lbs ( 0.15 kg) (Screw mounting), 0.37 lbs (0.17 kg) (DIN rail mounting)Non-magnetizing operation type17.5 (78)524 VDC ?10%
0.02 35 or less1250/20Ball screw + Belt (Motor parallel)Sliding bearing (LEYGlM), Ball bushing bearing (LEYGlL)41 to 104F (5 to 40C)90 RH or less (No condenstation)l4236Servo motor (24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 (0.15) (Screw mounting), 0.37 (0.17) (DIN rail mounting)Non-magnetizing operation type17.5524 VDC ?10%
Model LMU100 LMU200 ALF ALT Inlet air pressure Oil tank set pressure range Oil Dynamic viscosity of oil (40C) 0.1 to 1.0 MPa 0.05 to 0.2 MPa Turbine oil, Non-water soluble cutting oil (JIS, N1 type) 2 to 200 mm2/s Total capacity: 3000 Effective capacity: 2500 5 to 50C 100 VAC 50/60Hz, 200 VAC 50/60Hz, 24 VDC ALD ALB Oil tank capacity (cm3) Ambient and fluid temperature Solenoid valve voltage