Number SS070A 01 1A O-ring FKM 10 SS070A-80A-1 Port size Clip Stainless steel 10 SS070A-80A-2 With 3.18/2 barb fitting With 4/2.5 barb fitting 01 02 Metal joint Stainless steel 10 SS070A-80A-3 Leaf spring Stainless steel 10 SS070A-80A-4 Mounting bracket Stainless steel 10 SS070A-80A-5 < U Side End Plate Assembly > 2 U side end plate assembly No.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
unit PFW301 New Separate type PFW311 New PFW321 New PFW504 Sensor unit PFW520 New PFW540 3 Series PFA Digital Flow Switch for Air How to order 10 02 27 PFA7 Flow rate range 1 to 10l/min 5 to 50l/min 10 50 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications NPN (2 outputs) PNP (2 outputs) 27 67 Piping
(A) (A) (A) 2 (A) 2 2 2 1 (P) 3 (R) 1 (P) 3 (R) h h 1 (P) 3 (R) 1 (P) 3 (R) g g Component parts Replacement parts Description Body Piston plate End cover Piston Spool valve assembly Spool spring Material Aluminum die-casted Resin Aluminum die-casted Resin Stainless steel Note Zinc die-casted No.
OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .
For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Address setting switches 1, 2 and 3 ( SW1, SW2 and SW3 ) OFF N.C ON OFF ON With bus terminator Without bus terminator Without bus terminator OFF OFF ON OFF OFF ON OFF OFF ON SW3 1 1 2 100 10 SW3 SW2 0 1 2 9 8 7 6 SW2 3 4 5 0 1 2 0...9 SW1 0...9 9 8 7 6 SW1 3 4 5 0 1 2 1 Common to EX500-S 01/EX500-Q 20 21 Note1: For wiring method, refer to subsection "Wiring" ( page 10 ) of section "EX500"
5 Port Air Operated Valve Series VFRA3000 Model Configuration Port size Rc(PT) Effective area (mm2) (Cv) Pilot port size Rc(PT) Weight (kg) Valve model 1 4 3 8 37.8 (2.1) 41.4 (2.3) VFRA3111-03 VFRA3211-02 2 position double 0.71 1 8 VFRA3111-02 2 position single 0.61 1 8 1 4 3 8 37.8 (2.1) 41.4 (2.3) VFRA3211-03 VFRA3311-02 3 position closed center 0.72 1 8 1 4 3 8 34.2 (1.9) 36 (2.0) PA,
* 1015 10 1% 2162 LCD * -8No.PS-OMV0008CN-E ISE70G 02 L2 M 3 Y K T ISE70G 0~1 MPa ISE75G 0~2 MPa ISE76G 0~5 MPa ISE77G 0~10 MPa ISE78G 0~16 MPa 2 A A B B 02 Rc1/4 N02 NPT1/4 F02 G1/4 :ISO1179-1 1 M12 5m M12 5m T S : L IO-Link/1+2 NPNorPNP L2 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-48-A ZS-31-B 5 m M12 ZS-31-C 5 m -9No.PS-OMV0008CN-E M12 4 24 OUT1 IO-Link
-2No.PS-OMV0003CN-G / *3) 1 1.5 *3)1 1 [] -3No.PS-OMV0003CN-G () () () () -4No.PS-OMV0003CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMV0003CN-G * FG (35 N () ,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02
Blow setting Trigger setting 0 Slide Trigger linked 1 Trigger lock 2 OFF timer 3 s 3 5 s 4 7 s 5 Continuous blow Trigger linked 6 Trigger lock 7 OFF timer 3 s 8 5 s 9 7 s Pulse blow Mode setting switch Wiring AC adapter type IZG10-m01, 02 Connect the M8 connector on the power cable for AC adapter to the power connector on the main unit.
Single wiring 5 6 7 8 9 10 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A
13.5 15 41.6 28.5 R2 P R1 21 R P R 13 11 0.5 10 5 5 1(Bleed port) 210 10 7 7 1(Bleed port) 228 5-M3 0.5 (Piping port) 5-M5 0.8 (Piping port) 3 Position closed center / exhaust center / pressure center : SYJA3 20-M3(-F) 3 Position closed center / exhaust center / pressure center : SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 0.5 (Pilot port) 1.8 10 4 A B 1.5 8.2 7 19 (Mounting holes) 3.2 22-M3 0.5
(L): SYJ3 40-L-M5 M plug connector (M): SYJ3 40-M-M5 M8 connector (W0): SYJ3 40(R)-W0-M5 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 55.8 32.6 49.3 111.5 [115.9] R1 P R2 R1 P R2 R1 P R2 91.9 [96.3] 10 10 10 10 10 10 28 28 28 109.7 14 14 14 5 5 5 37.6 [39.8] 47.4 [49.6] 39.1 46.5 Refer to the page 91 for dimentions
21.5 28 34 41 6 6 6 8 16 21 25 30 6.3 12 10.3 18 7 10 11.5 14 3/16 3/16 +0.002 0 +0.002 0 +0.002 0 +0.002 0 +0.002 0 +0.002 0 #8-32UNC 3/16 3/16 #10-32UNF 5/16 5/16 1/4-28UNF 3/8 3/8 Knuckle pin and snap ring are contained.
suppressor) 41.5 [48.5] + 35.6 26.1 R1 P R2 13 5 10 10 10 M5 x 0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): SYJ3 40-L-M5 M plug connector (M): SYJ3 40-M-M5 M8 connector (WO): SYJ3 40(R)-WO-M5 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 55.8 32.6 49.3 111.5 [115.9] R1 P R2 R1 P R2 R1 P R2 91.9 [96.3]
Note 3) Polyurethane is only applicable for the ZFC050-02. SP ZCUK Made to Order (Refer to page 1115 for details.)