R Q2 B P C F(h9) D G1 G2 J K L M N Q1 E(g6) Q3 Model A 90 180 270 M5 M3 CRB1BW10-lS CRB1BW10-lSE CRB1BW15-lS CRB1BW15-lSE CRB1BW20-lS CRB1BW20-lSE CRB1BW30-lS CRB1BW30-lSE 3.4 (5.5) 5 8.5 5 11 9 14 10 15.5 25 9.5 25 10 25 13 25 14 M3 (6) 0 0.036 15 24 8 0.004 0.012 9 14 3 1 5 9 0.5 29 4 M3 M3 (5) M5 M3 3.4 (6) M3 (10) 0.004 0.012 0 0.043 20 29 9 12 18 5 4 1.5 6 10 0.5 34 M3 M4 (7.5) 4.5
PRESS. 1. 0 M Pa O U TPU T PRESS. 0. 010. 2 M Pa M AD E I N J APAN So G No. o S o1 T P2 U Q3 V R4 W Z12 6- (1) Nm 1/4 3/8 1/2 12~14 22~24 28~30 (2) (3) (4) 7- (1) (2) (3) (4) (1) (2) (3) (1) (2) O 3 (3) 3 (4) P.5 0 (5) 0 8- (1) (2) (3) 21Nm (4) ON-OFF 5 79Nm (6) (7) (8) 0.5MPa 0.1MPa (9) AN Rc1/2 (1) (2) 9- (1) (2) 1.5~2 (1) 1 1.5 (2) (3) a b
Ltd. 1 -800-sMc-s Mc 1 (7 62-7 621 ) For a branch office near you call: GEHMANY SMC Pneumatik GmbH SMC Corporation of America (Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 TEL: (770) 624-1940 FAX: (770) 624-1943 SMC Corporation of America (1.A.) 14191 Myford Road Tustin, CA 92780 fEL: (71$ 669-1701 FAX: (714) 669-1715 SMC Corporation of America (Seattle) 1 91 1 5 W.
32" Element Part Numbers 07 1/4" 09 5/16" Part No.
FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A
FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A
FMW-4300-2 .2 2 30 .1 .2 3A FMW-4300-5 .5 5 30 .2 .35 4A FMW-4300-15 .5 15 45 .4 .6 4A FMW-4300-30 .5 30 60 .6 1.0 4A FMW-4300-60 .5 60 120 1.5 2.5 4A FMW-4300-100 1 100 120 2.0 3.5 4A
IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options
IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options
Fittings & Tubing Air Cylinders Rotary Actuators 33.4 32 36 120 120 A C 32 8.5 8.5 Finger closing port Finger opening port M3 x 0.5 M3 x 0.5 9.5 3 x M3 x 0.5 thread depth 6 25 25 M3 x 0.5 Finger closing port P.C.D.24 (Mounting thread) M3 x 0.5 Finger opening port 31 9h9-0.036 0 1 32 5 15 19 10 5 (35) 7 14.5 M3 x 0.5 thread depth 4 6 x M3 x 0.5 thread depth 6 (A, B, C common view) Vacuum suction
5 10A FMW-4200-100 1 100 120 5.5 7.5 10A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.
5 10A FMW-4200-100 1 100 120 5.5 7.5 10A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.
5 10A FMW-4200-100 1 100 120 5.5 7.5 10A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.
Metric size 4, 6 Inch size 5/32", 1/4" Port size Rc, NPT 1/8 2 2 1 1 Pressure gauge port size Rc, NPT 1/8 (Width across flats) 11 M5 x 0.8 (Female thread) 26 26.1 3 R, NPT1/8 13.6 18.3 26.1 Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times.
/I.D. 1.4 MPa Fluid Air/Water (5) Maximum operating pressure (at 20C) 1.5 MPa 1 MPa 1.5 MPa 1 MPa 0.8 MPa 5 to 60C, Water: 0 to 40C (No freezing) Ambient and fluid temperature Connection size M5, R1/8 JIS B0205, Class 2 (Metric fine thread) M5 JIS B0205 (Metric fine thread) JIS B0203 (Taper thread for piping) Thread Note 1) Soft nylon tubing is not compatible with water.
(22) Nclise L.evel Construction/Dimensions (mm) 130 120 1 1 0 1()0 90 80 70 60 N2505 N2506 N?
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
D-864 Bone Sizes Rod Boot o75 -%', 088 -',6' 106 -1%6" 125 -114" 't50 -1%' J -Nylon K -Neoprene Astuation -Double Acting S -Spring Return T -Spring Extend srror,.rrn"r, Sirokg/Hundrlh ol an lnch Cushion' C -Rubber Bumper Note: Min. Strokes for Auto Switch Cylinders page 5. *Rubber Bumpers are no additional cost on 7s" & 174" bore size cylinderg. Thy are options on the other bore sizes.
Flow rate (l/min)(ANR) 3.6-7 Hand Valve Series VH Construction VH200 5 6 4 3 1 SlA 7 VlA 8 1 (P) SlA 4 (B) 2 (A) 2 3 (R) VlA VH300 / 400 5 6 VM/VR 4 3 VH 1 8 7 4 (B) 3 (R) 1 (P) 2 (A) 2 VH600 6 5 4 1 7 1 (P) 2 (A) 4 (B) 2 3 (R) Component Parts Material VH200/300/400 Zinc die cast Aluminium die cast VH600 Cast iron Description No.
80 60 10 60 40 1 AC DC AC/DC Maximum 10 (1) 5 (2) Minimum Note 1) Dew point is below 10C Note 2) Below 50 cSt Note 3) D, E, N, P, etc. in parentheses represents option symbol.