Do not put hands or fingers between the plate and body. Care should be taken that hands or fingers do not get caught in the space between the cylinder body and the plate when air pressure is applied. 1. Do not scratch or dent the sliding parts of the piston rod and guide rods. Damage to seals may cause air leaks or faulty operation. 2.
Do not move the cover upward inadvertently during end plate installation.
Do not apply pressure to this hole. Attach tubing to the vent hole and place the end of the tubing so it is not exposed to dust or water. For the rod end male thread, refer to page 247.
Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiated heat. 1. Cut the end of the tubing at a right angle and pass it through the fitting nut. After placing the tubing in the holder, push it onto the insert bushing until it stops and clamp it with the knob.
Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled.
Identifying Version Symbols For versions lower than V2.0 and S2.0: Do not use with controller parameters higher than V2.0 or S2.0. Applicable models Applicable models JXC91m Series JXCD1m Series JXCP1m Series JXCE1m Series For versions higher than V2.0 and S2.0: Do not use with controller parameters lower than V2.0 or S2.0.
Customers do not need to apply for a license to use this equipment. Be sure to comply with the following precautions. Do not disassemble or modify the product. Disassembly and modification are prohibited by law.
Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiated heat. LVA LVH LVD LVQ When the tubing is curved, straighten it out before using it. Maintenance The tubing may slip if there is oil or dust, etc., on the holder.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Specifications x100 IP address x 10 1 DIP SW Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Technical documentation giving detailed configuration information and the GSD file can be found on the SMC website (URL http://www.smcworld.com). Specifications Do not operate in an atmosphere containing flammable or explosive gases.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Connect valve manifold to the SI unit. Refer to the EX260 series valve manifold section in the valve catalogue for valve manifold dimensions. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Handling notes 6.1 Cautions for handling of the vertical auto switch unit (1) Be sure to connect a load to the switch before turning the power supply on. (2) Do not let objects drop onto or dent the product or subject it to strong impact when handling. (3) Do not use the product in the presence of a strong magnetic field. (4) When using two or more cylinders with auto switches closely in
The lock might not disengage or might become damaged if a load ratio of 50% is exceeded. t Do not synchronize multiple cylinders. Do not operate two or more end lock cylinders synchronized to move a single workpiece because, one of the cylinder locks may not be able to disengage when required. y Operate the speed controller under meter-out control.
11H9 Depth 1.5 35 Positioning pin hole MHZ2 47.5 9 MHZJ2 58 15 MHQ Auto switch mounting groove position M5 X 0.8 (Finger opening port) MHL2 MHR 3 O 13 MHK S MHS 3 4 23 7 M5 X 0.8 (Finger closing port) 2 MHC2 MHT2 MHY2-10D2 Opening/closing direction through hole type 43.4 MHY2 (Hole for mounting attachment) MHW2 6 0.005 0.025 3 6 MRHQ 12 Auto switch (Limited area for mounting attachment) Do
Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @
DO Without air cushion (mm) B Bore size (mm) No.
Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Manifolds SJ2000/3000, S0700 series : Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
No.6 No.5 No.8 No.7 No.10 No.9 Red flashing Wrong switch setting, Parameter writing error Green On Bus-off state, Duplicate MAC ID 16 32 4 8 1 2 Red flashing Off Green On I/O Connection is in the Timed-Out state Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.