Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 250mm
Protocol: EtherNet/IPâ„¢, Mounting: Screw Mounting, Cable Connector: w/o Plug Connector, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 500mm
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 400mm
Protocol: CC-Link, Mounting: DIN Rail Mounting, Cable Connector: Straight Type, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 400mm
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 150mm
Protocol: EtherNet/IPâ„¢, Mounting: Screw Mounting, Cable Connector: w/o Plug Connector, Actuator: Ball Screw, Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: 16: 5mm; 25: 6mm; 32: 8mm; 40: 20mm, Stroke: 400mm
EtherCAT Direct Connect, ELECTRIC ACTUATOR CONTROLLER, 0.13 lb
EtherCAT Direct Connect, ELECTRIC ACTUATOR CONTROLLER, 0.13 lb
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 2.13113 lb, ModelBoltMax. tightening torque (N m)L (mm)LESH25R/LM6 x 15.250.5
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator