SMC AXT625-01A-1-B manifold block, VF(S)100 SOL VALVE 3-PORT*** $32.53 Add to Quote Add To Cart Add to Cart SMC AXT625-01A-2 manifold assembly, VF(S)100 SOL VALVE 3-PORT***
Hmm 0.7MPa 0.3MPa 0.3MPa 60 0.7MPa 60 0.4MPa 0.4MPa 40 40 20 20 100 80 60 40 20 0 80 60 40 20 0 100 Gripping point L mm Gripping point L mm 3 Series MHF2 Confirmation of external force on fingers: Series MHF2 Step 3 L L Mr Mp Fv My L L: Distance to the point at which the load is applied (mm) Maximum allowable moment Allowable vertical load Fv (N) Model Pitch moment Mp (Nm) Yaw moment My(
S L, Z S L, Z 1 1 1 1 4 1 2 PB AC 2 Ordering example (Example) Series VXR22, Rc 1 1/4, 200 VAC, Conduit terminal (Part no.)
H 5 B C 100 S B F9N 1 Actuator configuration Number of auto switches/proximity switches Flat table type F 1 pc. 2 pcs. 1 2 Guide rod type P Slide table type S 6 pcs. 6 Guide type Direct acting guide H Auto switch/Proximity switch type Ball bushing B Without auto switch/proximity switch Nil With sensor plate, without proximity switch GN Proximity switches Motor type D-F9N (lead wire length
= 26 (Pitch) (P port) Max. 10 Max. 10 Mounting bracket n-Rc 1/8, 1/4 (A port) P = 26 L Dimension n: Stations Stations Formula L1 = 26 x n + 24 L2 = 26 x n + 12 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 L L1 L2 [ ]: With light/surge voltage suppressor 4-7-8
Piping: NPT1/8 w/M5 Female Thread, Output Specification: PNP Open Collector, 1 Output, Unit Specification: w/Unit Conversion Function (Not Allowed for Use in Japan), Option 1: -, Option 2: -
Piping: NPT1/8 w/M5 Female Thread, Output Specification: PNP Open Collector, 1 Output, Unit Specification: w/Unit Conversion Function (Not Allowed for Use in Japan), Option 1: -, Option 2: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8)
Model: -100 to 100kPa, Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: -, Operating Manual/Certificate: -, Made to Order: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -
Model: 0 to -101kPa, Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: -, Operating Manual/Certificate: -, Made to Order: -
Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: -, Operating Manual/Certificate: -, Made to Order: -
How to order (P.6). Attachment Protection cover With protective cover and attachments With protective cover. Without attachments Without protective cover and attachments Accessories Used for mounting this product and duAro flange. Refer to 4-3Mounting to duAro flange (P.15). Hexagon socket head cap Positioning pin (510) 1pc. screw (M510) 2 pcs. 4 - 2.
How to order (P.6). Attachment Protection cover With protective cover and attachments With protective cover Without attachments Without protective cover and attachments Accessories Used for mounting this product and NEXTAGE. Refer to 4-3Mounting to NEXTAGE (P.15). Hexagon socket head Flange 1pc. Positioning pin (610) 1pc. cap screw (M610) 2 pcs.
DRIVE bit 0,1 3 RESET bit 0,1 15 4 SETUP bit 0,1 5 bit 0 6 bit 0 7 bit 0 LECP6 LECA6 37 - Bit/Byte / Q_Address ID No. 0 1 16 1 063 1ABS 17 1 2INC() 18 H 2 065500 mm/s 19 L 20 3 21 2 4 2147483647 0.01mm 22 1 23 0 ID1 24 H 2 065500 mm/s2 25 L 26 H 2 065500 mm/s2 27 L 28 1 030 10% 29 1 030 10% 30 1 0255 mm/s 31 1 030 10% 32 H 2 065500 0.01mm 33 L ID2 3453 ID1 ID3 5473 ID1 ID4 7493