Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 8,400 / 9,800, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): 5000 or More, Supply Side Connection Type: [Rc (R)] R, Inlet Air Temperature(°C): 40, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 2, Control Side Connection
Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 11,000 / 12,400, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): 5000 or More, Supply Side Connection Type: [Rc (R)] R, Inlet Air Temperature(°C): 40, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 2, Control Side Connection
Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 2,800 / 3,100, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 5000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1, Control Side Connection
Size: 75 [300scfm, 510m³/hr (ANR)], Voltage: Three-phase, 460VAC, 60Hz, Connection Port Thread: Size 3 to 15, NPT Female; Size 22 to 75, NPT Male; 3/8" Drain Tube, Option: L+T
Size: 55 [226scfm, 384m³/hr (ANR)], Voltage: Three-phase, 460VAC, 60Hz, Connection Port Thread: Size 3 to 15, NPT Female; Size 22 to 75, NPT Male; 3/8" Drain Tube, Option: L+T
Size: 37 [6.1m³/min (ANR), 215.4scfm], Version: NIL (All Sizes Except 15), Voltage: 200VAC, 50Hz; 200/220VAC, 60Hz, 3 phase, Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: Terminal Block for Run & Alarm Signal
Size: 75 [12.5³/min (ANR), 441.43scfm], Version: NIL (All Sizes Except 15), Voltage: 200VAC, 50Hz; 200/220VAC, 60Hz, 3 phase, Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: Terminal Block for Run & Alarm Signal
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter,
This is a legacy product, and replaced byAS2200-N01
This is a legacy product, and replaced byAKM3000-N01
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)