SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AF-10-T"

Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15

A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)

S and Z types 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 8% to +10% 12 VDC: 6% to +10% Select the DC standard type or the power saving circuit type when the valve is continuously energized for long periods of time.

DS STROKE Bore E B1 B2 B3 TG1 T L1 L3 I1 I2 FL H d1 d2 d3 CN XD 32 45 14 34 3.3 32.5 3 11.5 41 5 5.5 22 10 30 10.5 6.6 10 142 40 55 16 40 4.3 38 4 12 48 5 5.5 25 10 35 11 6.6 12 160 50 65 21 45 4.3 46.5 4 14 54 5 6.5 27 10 40 15 9 16 170 63 75 21 51 4.3 56.5 4 14 60 5 6.5 32 12 45 15 9 16 190 80 95 25 65 4.3 72 4 16 75 5 10 36 16 45 18 11 20 210 100 115 25 75 6.3 89 4 16 85 5 10 41 16 55

-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =

capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-5 Cooling capacity(HRS100-A-20/40/46-) 8.4.2 HRS150-A-20/40/46: Ambient temperature: 32 oC : Ambient temperature: 40oC : Ambient temperature: 45 oC 18 18 16 16 14 14 Cooling capacity [kW] Cooling capacity [kW] 12 12 10 10 8 8 6 6

) CCW : CW : . 1) (2mm/) 2 1 CCW CW 2 3 OFF(ON) -28- (=) P.25 =02mm) =0 a) CCW 50mm =0() =10 50mm CCW CW 0 10 20 30 40 50 [mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,,

Please See Below for How to Order Piston Rod Assembly 7 Rod Bushing Bronze casting Available only as an Assembly Please See Rod/Head Cover NC1A400-10-124 NC1A200-10-124 NC1A250-10-124 NC1A325-10-124 8 Cushion Valve Carbon steel NC1A150-10-124 9 Tie Rod Carbon steel Please See Below for How to Order Tie Rod NCA325-13-Q6311 5008-131 NCA325-31-Q6311 NCA200-13-Q6309 5008-93 NCA250-13-Q6309 5008

level: 1 Air flow level: 1 10 10 10 10 Air flow level: 10 5 Air flow level: 10 5 Air flow level: 10 Air flow level: 10 5 5 Air flow level: 10 Air flow level: 10 5 5 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 0 0 0 0 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] 0 200 400

(mm) Model OO PP SS VV QQ RR TT UU Applicable gasket ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C14 17 23.5 53 40 12.5 34 26 10 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 x 0.8 M6 x 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120

(mm) Model OO PP SS VV QQ RR TT UU Applicable gasket ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C14 17 23.5 53 40 12.5 34 26 10 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 x 0.8 M6 x 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120

VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.

When requiring different port size, contact SMC. 02 Symbol No. of stations Type N 2 stations V 10 10 stations Manifold Optional Parts Option Body size Assembly part no. Attached parts 1 4 3 8 1 2 1 4 3 8 1 2 Blank plate XT015-4A XT016-5A XT038N-4A AXT394A AXT393A AXT396A Gasket, Bolt Interface speed control Gasket, Bolt Indicate valve and option number with the manifold base number.

N.O. 12(P1) port 10(P2) port Working Principle A port B port VND0 (N.C.) When fluid is exhausted from the P1 port, the valve r connected with the piston t is closed by the return spring y. When valve opens When pressurized air enters through the P1 port, the valve piston moves upward by the pilot air that enters below the piston and the valve element opens.

F F 1 2 1 2 MHL2-10DZ MHL2-16DZ MHL2-16D Z MHL2-10D Z 60 60 25 25 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa 50 50 20 20 Pressure 0.6 MPa 0.5 MPa Pressure 0.6 MPa 0.5 MPa 40 40 15 15 0.4 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 0.4 MPa 10 10 0.3 MPa 20 20 0.3 MPa 0.3 MPa 0.3 MPa 0.2 MPa 5 5 10 10 0.2 MPa 0.2 MPa 0.2 MPa 10

L d m t M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 5 6 8 11 13 16 13 17 22 27 32 41 15.0 19.6 25.4 31.2 37.0 47.3 NT-02 NT-03 NT-04 NT-05 NT-08 NT-10 0.040 0.076 8 20 C8 type for pivot 21 7.6 16.2 1.5 0.9 IY-G02 0.040 0.076 10 25 C10 type for pivot 25.6 9.6 20.2 1.55 1.15 IY-G03 0.040 0.076 10 32,40 C10 type for pivot 41.6 9.6 36.2 1.55 1.15 IY-G04 0.050 0.093 14 50,63 C14

14 20 10 20 10 (All dimensions but A and CL are identical to those of the basic style.)

Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications