SMC Corporation of America
Elite Part Number Search
Search Results "PF3W504S-03-2-R"

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: DG (D + G), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: BC (B + C), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: BG (B + G), Semi-Standard 1: 2J (2 + J), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Standard

Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: BD (B + D), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Standard

Actuation Type: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)

Body Size: 40, Thread: N (NPT), Port: 03 (3/8), Option: Standard, Attachment: T (T-spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: BC (B + C), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: BD (B + D), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping)

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Model: 1FS, Thread: R (or None), Port Size: 03 (3/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)

Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: T (NPTF)

Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8)

Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: R (External Pilot), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)