Body Size: 40, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 06 (3/4), Option: BC (B + C), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Body Size: 50, Thread: N (NPT), Port Size: 06 (3/4), Option: B (Bracket), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: B (Bracket), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: LT [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: Yes]
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; Stop Valve: None), Return Port Size: 06 (3/4), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; Stop Valve: None), Return Port Size: 06 (3/4), Flow Switch Output Specifications: 2 (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; Stop Valve: None), Return Port Size: 06 (3/4), Flow Switch Output Specifications: 2 (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve: None; Stop Valve: None, Return Port Size: 06 (3/4), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 1 (180°), Thread: R, Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 06 (ø6)