/m 3] 100,000 100,000 0/mi n(ANR) ISOclass6 50/mi n(ANR) 10,000 10,000 ISOclass5 ISOclass5 30/mi n(ANR) 1,000 1,000 ISOclass4 ISOclass4 100 100 90/mi n(ANR) 10 10 50/mi n(ANR) 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particl diameter[m] Particl diameter[m] 2.2 Amount of vacuum aspiration The amount of recommended vacuum aspiration according to the clean time class is shown
VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz 3 Note 2) 2 1 Orifice dia.
From the above 2. position, turn the adjustment needle 1/4 to 1 turn clockwise. 1 kPa = 7.5 mmHg 1 kPa = 7.5 mmHg 101 101 Supply pressure (kPa) Supply pressure (kPa) Applicable adsorption nozzle range Applicable adsorption nozzle range 50 50 3. 2. 1. 20 20 ZSE ISE Right 0.2 0.3 0.4 0.5 0.6 0.7 0.3 0.5 0.7 0.9 1.1 1/4 to 1 turn Right Left PSE Adsorption nozzle diameter (mm) Adsorption nozzle
Made to Order (Please contact SMC for specifications in detail, dimensions and delivery.) 10 m roll 50 m reel 100 m reel Model TFU0425 TFU0604 TFU0805 TFU1065 TFU1208 1. Change of color (10 m roll) 4 Tubing O.D. (mm) 6 8 10 12 Suffix -X4 to the end of part number. Ex.) TFU0604BU-2-10X4 2.5 Tubing I.D.
Base cylinder lubrication Non-lube +1.9 +0.2 0.07 +1.9 mm Stroke length tolerance MGP Note 1) Slide bearing 0.06 0.06 0.05 0.04 Non-rotating accuracy MGQ 0.06 0.05 0.04 0.04 0.04 Ball bushing bearing Note 2) Piping port size (Rc, NPT, G) M5 x 0.8 1/8 1/4 MGG 1 When the cylinder is retracted (initial value), the non-rotating accuracy without loads or deflection of the guide rods will be below
Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input
s o.50 o.8e4 o93 0.75 0.18 %-18 0.50 0.95 2.94 106 (1 0.312 %-24 0.50 o.624 0.25 1.12 o.12 0.88 0.88 0.24 %-8 0.62 1.17 3.25 0.la7 Wzo 0.75 0.7i19 o 1.t2 0.25 1.06 'L06 o.25 %-16 ora 1.62 400 150 t1%l o.87 1h-20 o_75 o.749 0.38 1.56 0.25 1.25 1.25 o.25 3l-16 0.88 '1.50 3.69 Double End : NC.
8, @1. HYCB32-PS HYCB40-PS HYCB50-PS HYCB63-PS 32 40 50 63 !5 !6 !7 !8 19 @1 Cushion seal Rod seal Resin NBR (FKM can be selected.) 1 HYCB50H-PS Set of left nos. !5, !6, !7, !8, @1. Rod seal Piston seal NBR (FKM can be selected.) 1 NBR 1 HYCB63H-PS Piston seal Cylinder tube gasket NBR 1 NBR 2 (FKM can be selected.) Place the seal material symbol in .
8, @1. HYCB32-PS HYCB40-PS HYCB50-PS HYCB63-PS 32 40 50 63 !5 !6 !7 !8 19 @1 Cushion seal Rod seal Resin NBR (FKM can be selected.) 1 HYCB50H-PS Set of left nos. !5, !6, !7, !8, @1. Rod seal Piston seal NBR (FKM can be selected.) 1 NBR 1 HYCB63H-PS Piston seal Cylinder tube gasket NBR 1 NBR 2 (FKM can be selected.) Place the seal material symbol in .
) 50 to 500 mm/s Piston speed None Cushion +1.0 0 Symbol Specifications Stroke length tolerance -XC17 Pin cylinder with rod quenched JIS Class 2 Thread tolerance -XC22 Fluoro rubber seals With thread/Without thread Rod end configuration Panel mounting style Plug mounting style Mounting bracket Mounting nut (1) Gasket (1) Rod end nut (2) Mounting nut (2) Rod end nut (2) Standard equipment
) 50 to 500 mm/s Piston speed None Cushion +1.0 0 Symbol Specifications Stroke length tolerance -XC17 Pin cylinder with rod quenched JIS Class 2 Thread tolerance -XC22 Fluoro rubber seals With thread/Without thread Rod end configuration Panel mounting style Plug mounting style Mounting bracket Mounting nut (1) Gasket (1) Rod end nut (2) Mounting nut (2) Rod end nut (2) Standard equipment
(This is to prevent the setting from remaining incomplete if, for instance, an operator were to leave during setting) : 3 step setting mode and Function selection mode are reflected on each other. 1 2 [ 50] 50 L/min (PFMB7102) [ 100] 100 L/min (PFMB7202) System error An internal data error has occurred. Turn the power OFF and turn it ON again.
MIS-A2504 MIS-A2504 MIS25-PS MI-A3201-30 MI-A3202-30 MI-A3203-30 MI-A3201-50 MI-A3202-50 MI-A3203-50 MIS32-PS MIS-A3204 MIS-A3204 MIS32-PS Main parts No. e (1 pc.) !
Standard Stroke Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125, 150 20 to 63 Theoretical Output OUT IN 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125 80, 100 Unit: N Manufacture of Intermediate Stroke Bore size (mm) Operating direction Operating pressure (MPa) 0.3 0.5 0.7 Dealing with the stroke by the 1 mm interval by using an exclusive
MIS-A2504 MIS-A2504 MIS25-PS MI-A3201-30 MI-A3202-30 MI-A3203-30 MI-A3201-50 MI-A3202-50 MI-A3203-50 MIS32-PS MIS-A3204 MIS-A3204 MIS32-PS Main parts No. e (1 pc.) !
buffer, axial piping 6 Centralized adjuster 7 Centralized adjuster (Symmetric) 8 Buffer, Centralized adjuster 9 Buffer, Centralized adjuster (Symmetric) Nil 2 S 1 n n Port Switch mounting groove Port Switch mounting groove 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 For details, refer to the next page. i Made to order 16 10, 20, 30, 40, 50, 75, 100, 125 Port Switch mounting groove
1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !2 !3 !2 !3 !2 !3 63 !2 !3 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series HYQ. 63 63 63 Seal Kit List Description Material Note No. Seal Kit List Description Material Note No. o !0 11 o !0 11 Rod seal Rod seal (FKM can be selected.)
1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !1 o !4 !2 !0 !3 !2 !3 !2 !3 !2 !3 63 !2 !3 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series HYQ. 63 63 63 Seal Kit List Description Material Note No. Seal Kit List Description Material Note No. o !0 11 o !0 11 Rod seal Rod seal (FKM can be selected.)
SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
The overall Cv of a tube and valve system is calculated by combining the Cv of each element as follows: 1 Cv 2 syst 1 Cv1 2 1 Cv2 2 1 Cv3 2 etc Quick approximate calculation can be made by assuming 50% of system pressure drop is made at the valve and 50% in the tube system.