Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes]
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Model number: HRS060-N-20 The transition connector from Rc to NPT is enclosed as an accessory. For NPT piping, be sure to use this connector. Model number: HRS060-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
N Number of stations It is the total of the occupation station of all slaves station connected in CCLink. O Occupied number of stations Number of the stations on the network which one slave station uses. It is possible to set from Station 1 to Station 4 according to the number of the data. P PLC Abbreviation of Programmable Logic Controller.
Displ m Displ m Block diagram spring Compd. spring Compd. m M Pa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
Displ m Displ m Block diagram spring Compd. spring Compd. m M Pa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
M Pa MPa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m2 Block diagram Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
FAN IONIZER, PNP, 3M CABLE, OTHERS, IZS/IZF IONIZER, 2X, IZSE30 NO SIZE RATING, 3.61353 lb
HECR002 HECR004 HECR006 HECR008 5 Installation N L HECR010 5.1 Installation Power supply connector N AC100 to 240V AC200 to 240V (IEC60320,C14) E L AC100 to 240V AC200 to 240V Pay special attention to the safety of all personnel when installing and 1) Select "2" in control operation. 2) Pressing [AT] key to light "AT" indicator and start auto tuning. 3) Pressing [AT] key stops auto tuning
P 1 Exhaust cleaner Exhaust cleaner Solenoid Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inlet pressure for exhaust cleaner Valve 3. If compressed air exhausted from the solenoid valve is not clean clogging may occur, 4.
d i a n a p o l i s, I N ROCHESTER, NY (716) 321-1300 Vacuum Pad Series ZP Replacement Parts: Pad unit (With lock ring/Without lock ring) Pad Unit/How to Order Lock Ring Unit/How to Order ZPL 1 X19 U N 10 ZP Applicable pad dia.
NEW ZEALAND SMC Pneumatics (N.2.) Ltd.
None Symbol Input/Output Nil NPN P PNP 18 IZT40/41/42 Series Made to Order Symbol Description Specifications -X10 Non-standard bar length Manufacturable bar length (Symbol): 10 + 6 x n (n: Integer from 1 to 39) (For n = 1, 2, 4, 5, 6, 8, 9, 12, 17, 20, 25, 30, and 37, use a standard model.)
Bore size [mm] (Pressure receiving diameter) 4 6 10 16 20 Operating pressure range [MPa] Weight of moving parts [g] 4 8 24 62 103 Thrust control standard [N] 0.01 to 8 0.03 to 19 0.08 to 50 0.20 to 140 0.30 to 200 Stroke [mm] 0.001 to 0.7 10 (Except for moving parts weight) Features 3 (Metal Seal Type/Single Acting) /4, 6, 10, 16, 20 control range of 0.01 N to 200 N Application Examples