Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: Panel Mount Adapter for w/Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection, easy operation, and standardization of CE, UL/CSA and RoHS compliance. 4 indicator patterns of color combinations , Choice of 2 piping directions rear and bottom ported , Panel or bracket mounting , Resolution and MPa/kPa switching function , Analog current output, Y,
from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection, easy operation, and standardization of CE, UL/CSA and RoHS compliance. 4 indicator patterns of color combinations , Choice of 2 piping directions rear and bottom ported , Panel or bracket mounting , Resolution and MPa/kPa switching function , Analog current output, Y,